CVE-2026-11389
Out-of-bounds Read, Function Call With Incorrect Number of Arguments, Access of Resource Using Incompatible Type ('Type Confusion') vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers. This issue affects Connext Professional: from 7.4.0 before 7.7.0.1, from 7.3.0 before 7.3.1.6.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 6.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.10%
- Percentil entre todas las CVEs puntuadas: 1
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1068Exploitation for Privilege Escalationprivilege escalation85 % - Impacto principal
T1499.004Application or System Exploitationimpact75 % - Impacto secundario
T1005Data from Local Systemcollection60 %
Vector AV:L/PR:L indica acceso local con privilegios. CWE-125/843 (out-of-bounds read, type confusion) en bibliotecas core permite escalar o causar DoS. Lectura de memoria en buffer confirma T1005 secundario.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-125, CWE-685, CWE-843
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-11389",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-11389",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-09-22T18:49:09.272083Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "3f572a00-62e2-4423-959a-7ea25eff1638",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 6.8,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "3f572a00-62e2-4423-959a-7ea25eff1638",
"affectedData": [
{
"vendor": "RTI",
"modules": [
"Core Libraries"
],
"product": "Connext Professional",
"versions": [
{
"status": "affected",
"version": "7.4.0",
"lessThan": "7.7.0.1",
"versionType": "custom"
},
{
"status": "affected",
"version": "7.3.0",
"lessThan": "7.3.1.6",
"versionType": "custom"
}
],
"packageURL": "pkg:generic/connext_professional",
"packageName": "connext_professional",
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-09-22T18:17:10.673",
"references": [
{
"url": "https://www.rti.com/vulnerabilities/#cve-2026-11389",
"source": "3f572a00-62e2-4423-959a-7ea25eff1638"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "3f572a00-62e2-4423-959a-7ea25eff1638",
"description": [
{
"lang": "en",
"value": "CWE-125"
},
{
"lang": "en",
"value": "CWE-685"
},
{
"lang": "en",
"value": "CWE-843"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Out-of-bounds Read, Function Call With Incorrect Number of Arguments, Access of Resource Using Incompatible Type ('Type Confusion') vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers. This issue affects Connext Professional: from 7.4.0 before 7.7.0.1, from 7.3.0 before 7.3.1.6."
}
],
"lastModified": "2026-09-22T19:37:36.747",
"sourceIdentifier": "3f572a00-62e2-4423-959a-7ea25eff1638"
}