CVE-2026-111855
An issue was discovered on Tektronix 3 Series MDO devices before 1.21.1. A path traversal vulnerability exists in the web management interface of the device. Insufficient validation of user-supplied file paths allows remote attackers to read arbitrary files accessible to the application. Depending on configuration, exploitation may be possible without authentication.
CVSS
- Base score
- 7.5
- Version
- 3.1
- Vector
- CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days
- 0.49 %
- Percentile among all scored CVEs
- 41
- Score date
- 10/20/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
ATT&CK techniques
How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.
- Exploitation
T1190Exploit Public-Facing Applicationinitial access90 % - Primary impact
T1005Data from Local Systemcollection85 % - Secondary impact
T1552Unsecured Credentialscredential access35 %
Path traversal en la interfaz web (AV:N, PR:N) permite leer archivos arbitrarios del dispositivo; el texto indica lectura de archivos, sin mencionar credenciales explícitas.
Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.
ATT&CK mitigations that cover these techniques
Affected technologies (1)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
CWEs
- CWE-22
References
Raw JSON (NVD)
Show
{
"id": "CVE-2026-111855",
"cveTags": [],
"metrics": {
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cve@mitre.org",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "Tektronix",
"product": "3 Series MDO",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.21.1",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-10-17T02:17:18.877",
"references": [
{
"url": "https://download.tek.com/document/TEK-PSA-002-092026.pdf",
"source": "cve@mitre.org"
},
{
"url": "https://www.tek.com/en/products/oscilloscopes/3-series-mdo",
"source": "cve@mitre.org"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Primary",
"source": "cve@mitre.org",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Tektronix 3 Series MDO devices before 1.21.1. A path traversal vulnerability exists in the web management interface of the device. Insufficient validation of user-supplied file paths allows remote attackers to read arbitrary files accessible to the application. Depending on configuration, exploitation may be possible without authentication."
}
],
"lastModified": "2026-10-19T21:13:39.973",
"sourceIdentifier": "cve@mitre.org"
}