CVE-2026-108917
A vulnerability was determined in Edimax BR-6208AC 1.32. This issue affects some unknown processing of the file /goform/formAutoFWupgrade. Executing a manipulation of the argument tftpsIP can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer.
CVSS
- Base score
- 9.3
- Version
- 4.0
- Vector
- CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days
- 1.99 %
- Percentile among all scored CVEs
- 80
- Score date
- 10/21/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
ATT&CK techniques
How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.
- Exploitation
T1190Exploit Public-Facing Applicationinitial access95 % - Primary impact
T1059Command and Scripting Interpreterexecution90 %
Vector CVSS de red sin autenticación (AV:N/PR:N) más CWE-74/77 (inyección de comandos) en parámetro tftpsIP accesible remotamente; ejecución de código remoto confirmada por descripción de manipulación de argumentos.
Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.
ATT&CK mitigations that cover these techniques
Affected technologies (1)
⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.
CWEs
- CWE-74, CWE-77
References
Raw JSON (NVD)
Show
{
"id": "CVE-2026-108917",
"cveTags": [
{
"tags": [
"unsupported-when-assigned"
],
"sourceIdentifier": "cna@vuldb.com"
}
],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-108917",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-10-13T16:03:40.017470Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 10,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 10,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 9.3,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "PROOF_OF_CONCEPT",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:edimax:br-6208ac_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "Edimax",
"product": "BR-6208AC",
"versions": [
{
"status": "affected",
"version": "1.32"
}
]
}
]
}
],
"published": "2026-10-12T18:17:22.163",
"references": [
{
"url": "https://github.com/fizz-is-on-the-way/Iot_vuls/tree/main/BR-6208AC/RCE_formAutoFWupgrade",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/cve/CVE-2026-108917",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/submit/977199",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/vuln/416729",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/vuln/416729/cti",
"source": "cna@vuldb.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-74"
},
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Edimax BR-6208AC 1.32. This issue affects some unknown processing of the file /goform/formAutoFWupgrade. Executing a manipulation of the argument tftpsIP can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way. This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"lastModified": "2026-10-13T17:17:22.140",
"sourceIdentifier": "cna@vuldb.com"
}