« Back to list

CVE-2026-102255

Status: Awaiting AnalysisCritical (10)—

A Pre-authentication SSRF vulnerability exists in the SMA1000 Appliance Work Place interface due to an unintended alternate access path. By abusing this path, a remote unauthenticated attacker could potentially exploit this vulnerability to direct the appliance to issue requests on their behalf and reach internal functionality and perform unauthorized operations.

CVSS

Exploitation probability (EPSS)

FIRST hasn't scored this CVE yet (usual for very recent or rejected CVEs).

EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).

📰 Media coverage

Specialised security media that have cited this CVE:

Affected technologies (1)

⚠ AI-inferred from the description — NVD hasn't analyzed this CVE yet, these aren't verified CPEs.

CWEs

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2026-102255",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-102255",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-10-07T15:50:57.013778Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 10,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "PSIRT@sonicwall.com",
      "affectedData": [
        {
          "vendor": "SonicWall",
          "product": "SMA1000",
          "versions": [
            {
              "status": "affected",
              "version": "12.4.3-03526 (platform-hotfix) and older versions"
            },
            {
              "status": "affected",
              "version": "12.5.0-02952 (platform-hotfix) and older versions"
            }
          ],
          "platforms": [
            "Linux"
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2026-10-07T13:17:16.387",
  "references": [
    {
      "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2026-0017",
      "source": "PSIRT@sonicwall.com"
    }
  ],
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "PSIRT@sonicwall.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-441"
        },
        {
          "lang": "en",
          "value": "CWE-918"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A Pre-authentication SSRF vulnerability exists in the SMA1000 Appliance Work Place interface due to an unintended alternate access path. By abusing this path, a remote unauthenticated attacker could potentially exploit this vulnerability to direct the appliance to issue requests on their behalf and reach internal functionality and perform unauthorized operations."
    }
  ],
  "lastModified": "2026-10-07T16:17:32.440",
  "sourceIdentifier": "PSIRT@sonicwall.com"
}