« Volver al listado

CVE-2026-102110

Estado: En análisisMedia (5.9)—

An endpoint used during initial appliance setup did not require authentication and did not correctly enforce its intended state precondition, so during the initial activation window an unauthenticated network attacker could repeatedly re-trigger the privileged activation process. This could disrupt setup and leave the appliance in an incompletely configured state. The issue is only reachable while an appliance is being activated for the first time and not yet fully configured.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Inferido por reglas deterministas a partir del vector CVSS y la CWE. Solo orientativo.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-102110",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-102110",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-10-01T13:19:49.178577Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "9119a7d8-5eab-497f-8521-727c672e3725",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.9,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.2
      }
    ]
  },
  "affected": [
    {
      "source": "9119a7d8-5eab-497f-8521-727c672e3725",
      "affectedData": [
        {
          "vendor": "Kiteworks",
          "product": "Core",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "9.5.1",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "9.5.1"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2026-09-30T21:16:57.990",
  "references": [
    {
      "url": "https://github.com/kiteworks/security-advisories/security/advisories/GHSA-qfqh-c638-m5pg",
      "source": "9119a7d8-5eab-497f-8521-727c672e3725"
    },
    {
      "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/VA/white/2026/va-26-274-01.json",
      "source": "9119a7d8-5eab-497f-8521-727c672e3725"
    }
  ],
  "vulnStatus": "Undergoing Analysis",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "9119a7d8-5eab-497f-8521-727c672e3725",
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        },
        {
          "lang": "en",
          "value": "CWE-670"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An endpoint used during initial appliance setup did not require authentication and did not correctly enforce its intended state precondition, so during the initial activation window an unauthenticated network attacker could repeatedly re-trigger the privileged activation process. This could disrupt setup and leave the appliance in an incompletely configured state. The issue is only reachable while an appliance is being activated for the first time and not yet fully configured."
    }
  ],
  "lastModified": "2026-10-01T14:17:14.907",
  "sourceIdentifier": "9119a7d8-5eab-497f-8521-727c672e3725"
}