CVE-2026-0653
On TP-Link Tapo C260 v1 and D235 v1, a guest‑level authenticated user can bypass intended access restrictions by sending crafted requests to a synchronization endpoint. This allows modification of protected device settings despite limited privileges. An attacker may change sensitive configuration parameters without authorization, resulting in unauthorized device state manipulation but not full code execution.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.41%
- Percentil entre todas las CVEs puntuadas: 33
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1565.001Stored Data Manipulationimpact70 % - Impacto secundario
T1078.001Default Accountsstealth · persistence · privilege escalation · initial access60 %
AV:N PR:L requiere red y privilegios (cuenta guest autenticada); sincronización manipulable → modificación de configuración remota. Sin ejecución de código explícita.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-284
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2026-0653",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-0653",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-02-11T15:07:58.044112Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.2,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"affectedData": [
{
"vendor": "TP-Link Systems Inc.",
"product": "Tapo C260 v1",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.1.9 Build 251226 Rel.55870n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "Tapo D235 v1",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.2.2 Build 260210 Rel.27165n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-02-10T18:16:22.257",
"references": [
{
"url": "https://www.tp-link.com/en/support/download/tapo-c260/v1/",
"tags": [
"Product"
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
},
{
"url": "https://www.tp-link.com/en/support/download/tapo-d235/",
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
},
{
"url": "https://www.tp-link.com/us/support/download/tapo-c260/v1/",
"tags": [
"Product"
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
},
{
"url": "https://www.tp-link.com/us/support/faq/4960/",
"tags": [
"Vendor Advisory"
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On TP-Link Tapo C260 v1 and D235 v1, a guest‑level authenticated user can bypass intended access restrictions by sending crafted requests to a synchronization endpoint. This allows modification of protected device settings despite limited privileges. An attacker may change sensitive configuration parameters without authorization, resulting in unauthorized device state manipulation but not full code execution."
},
{
"lang": "es",
"value": "En TP-Link Tapo C260 v1, un usuario autenticado con nivel de invitado puede eludir las restricciones de acceso previstas enviando solicitudes manipuladas a un endpoint de sincronización. Esto permite la modificación de la configuración protegida del dispositivo a pesar de los privilegios limitados. Un atacante puede cambiar parámetros de configuración sensibles sin autorización, resultando en una manipulación no autorizada del estado del dispositivo, pero no en la ejecución completa de código."
}
],
"lastModified": "2026-06-17T10:11:09.230",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:tapo_c260_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FD5A8252-3DA6-4C0D-AF45-F19BCBDBEF95",
"versionEndExcluding": "1.1.9"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:tapo_c260:1:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "26590B2F-AD6F-467B-813C-18972794C1F6"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630"
}