« Volver al listado

CVE-2026-0515

Estado: AplazadaMedia (6.2)—

Insufficient Parameter Validation in the SchedGet() system call could allow an attacker with local access to cause a crash of the QNX Neutrino kernel.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2026-0515",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2026-0515",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-07-14T23:35:18.765970Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "secure@blackberry.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.2,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.5
      }
    ]
  },
  "affected": [
    {
      "source": "secure@blackberry.com",
      "affectedData": [
        {
          "vendor": "BlackBerry Ltd",
          "product": "QNX Software Development Platform",
          "versions": [
            {
              "status": "affected",
              "version": "7.1"
            },
            {
              "status": "affected",
              "version": "cpe:2.3:a:blackberry:qnx_software_development_platform:7.1:*:*:*:*:*:*:*",
              "versionType": "cpe"
            },
            {
              "status": "affected",
              "version": "7.0"
            },
            {
              "status": "affected",
              "version": "cpe:2.3:a:blackberry:qnx_software_development_platform:7.0:*:*:*:*:*:*:*"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "BlackBerry Ltd",
          "product": "QNX OS for Safety",
          "versions": [
            {
              "status": "affected",
              "version": "2.2.8 and earlier"
            },
            {
              "status": "affected",
              "version": "cpe:2.3:o:blackberry:qnx_os_for_safety:2.2:8:*:*:*:*:*:*",
              "versionType": "cpe"
            },
            {
              "status": "affected",
              "version": "2.1.5 and earlier"
            },
            {
              "status": "affected",
              "version": "cpe:2.3:o:blackberry:qnx_os_for_safety:2.1:5:*:*:*:*:*:*",
              "versionType": "cpe"
            },
            {
              "status": "affected",
              "version": "2.0.3 and earlier"
            },
            {
              "status": "affected",
              "version": "cpe:2.3:o:blackberry:qnx_os_for_safety:2.0:3:*:*:*:*:*:*",
              "versionType": "cpe"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "BlackBerry Ltd.",
          "product": "QNX OS for Medical",
          "versions": [
            {
              "status": "affected",
              "version": "2.0.2 and earlier"
            },
            {
              "status": "affected",
              "version": "cpe:2.3:o:blackberry:qnx_os_for_medical:2.0:2:*:*:*:*:*:*",
              "versionType": "cpe"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-07-14T18:17:10.650",
  "references": [
    {
      "url": "https://support.blackberry.com/pkb/s/article/141213",
      "source": "secure@blackberry.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "secure@blackberry.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-233"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Insufficient Parameter Validation in the SchedGet() system call could allow an attacker with local access to cause a crash of the QNX Neutrino kernel."
    }
  ],
  "lastModified": "2026-07-15T16:24:31.140",
  "sourceIdentifier": "secure@blackberry.com"
}