CVE-2025-8703
Estado: AnalizadaBaja (2.1)—
A vulnerability classified as critical was found in Wanzhou WOES Intelligent Optimization Energy Saving System 1.0. This vulnerability affects unknown code of the file /WEAS_HomePage/GetAreaTrendChartData of the component Environmental Real-Time Data Module. The manipulation of the argument energyId leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 2.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.34%
- Percentil entre todas las CVEs puntuadas: 25
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-74, CWE-89
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-8703",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-8703",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-08-08T17:13:15.704240Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 6.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 2.1,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "LOW",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "PROOF_OF_CONCEPT",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "LOW",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Wanzhou",
"modules": [
"Environmental Real-Time Data Module"
],
"product": "WOES Intelligent Optimization Energy Saving System",
"versions": [
{
"status": "affected",
"version": "1.0"
}
]
}
]
}
],
"published": "2025-08-08T01:15:25.463",
"references": [
{
"url": "https://github.com/si12/xxx/issues/3",
"tags": [
"Exploit",
"Issue Tracking"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.319132",
"tags": [
"Permissions Required",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.319132",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?submit.621278",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-74"
},
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Wanzhou WOES Intelligent Optimization Energy Saving System 1.0. This vulnerability affects unknown code of the file /WEAS_HomePage/GetAreaTrendChartData of the component Environmental Real-Time Data Module. The manipulation of the argument energyId leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "es",
"value": "Se detectó una vulnerabilidad crítica en Wanzhou WOES Intelligent Optimization Energy Saving System 1.0. Esta vulnerabilidad afecta al código desconocido del archivo /WEAS_HomePage/GetAreaTrendChartData del componente Environmental Real-Time Data Module. La manipulación del argumento energyId provoca una inyección SQL. El ataque puede ejecutarse en remoto. Se ha hecho público el exploit y puede que sea utilizado."
}
],
"lastModified": "2026-06-17T10:07:28.287",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:wanzhou:woes_intelligent_optimization_energy_saving_system:1.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "249090F6-5928-4E3A-9251-53BB16F4073E"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cna@vuldb.com"
}