CVE-2025-7973
A security issue exists in FactoryTalk ViewPoint version 14.0 or below due to improper handling of MSI repair operations. During a repair, attackers can hijack the cscript.exe console window, which runs with SYSTEM privileges. This can be exploited to spawn an elevated command prompt, enabling full privilege escalation.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.14%
- Percentil entre todas las CVEs puntuadas: 3
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1068Exploitation for Privilege Escalationprivilege escalation95 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 % - Impacto secundario
T1548Abuse Elevation Control Mechanismprivilege escalation85 %
Acceso local con privilegios (PR:L) sin interacción del usuario permite escalar a SYSTEM mediante hijacking de proceso cscript.exe durante reparación MSI, obteniendo ejecución de comandos elevada (CWE-268, improper privilege handling).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-268
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-7973",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-7973",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-08-14T13:58:39.358370Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.5,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "PSIRT@rockwellautomation.com",
"affectedData": [
{
"vendor": "Rockwell Automation",
"product": "FactoryTalk® ViewPoint",
"versions": [
{
"status": "affected",
"version": "Version 14.00 or below"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-08-14T14:15:35.847",
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1738.html",
"source": "PSIRT@rockwellautomation.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"description": [
{
"lang": "en",
"value": "CWE-268"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A security issue exists in FactoryTalk ViewPoint version 14.0 or below due to improper handling of MSI repair operations. During a repair, attackers can hijack the cscript.exe console window, which runs with SYSTEM privileges. This can be exploited to spawn an elevated command prompt, enabling full privilege escalation."
},
{
"lang": "es",
"value": "Existe un problema de seguridad en FactoryTalk ViewPoint versión 14.0 o anterior debido a la gestión incorrecta de las operaciones de reparación de MSI. Durante una reparación, los atacantes pueden secuestrar la ventana de consola cscript.exe, que se ejecuta con privilegios de SYSTEM. Esto puede aprovecharse para generar un símbolo del sistema con privilegios elevados, lo que permite una escalada completa de privilegios."
}
],
"lastModified": "2026-06-17T10:06:04.330",
"sourceIdentifier": "PSIRT@rockwellautomation.com"
}