CVE-2025-7972
A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers.
Timeline
Built from our own data: NVD, CISA KEV and other exploitation catalogues, FIRST EPSS, public exploits, specialised media and Orbitaley coverage.
- CVE record published in NVD
- Record last modified in NVD
ATT&CK techniques
How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.
- Exploitation
T1068Exploitation for Privilege Escalationprivilege escalation85 % - Primary impact
T1565Data Manipulationimpact80 % - Secondary impact
T1078Valid Accountsstealth · persistence · privilege escalation · initial access75 %
Acceso local sin privilegios (AV:L/PR:N) que permite modificar configuración (NODE_ENV) para eludir validación y alterar drivers (T1565) y acceder a funciones administrativas (T1078). CWE-286: Improper Authentication.
Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.
ATT&CK mitigations that cover these techniques
Affected technologies (1)
NVD record
- NVD status
- Analyzed
- Published
- Aug 14, 2025
- Last modified
- Jun 17, 2026
- CVSS vector
- CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Weakness (CWE)
- CWE-286
References
Raw JSON (NVD)
Show
{
"id": "CVE-2025-7972",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-7972",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-08-14T15:06:45.964707Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.1,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 5.2,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.4,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "PSIRT@rockwellautomation.com",
"affectedData": [
{
"vendor": "Rockwell Automation",
"product": "FactoryTalk® Linx",
"versions": [
{
"status": "affected",
"version": "All prior to 6.50"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-08-14T15:15:42.413",
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1735.html",
"tags": [
"Vendor Advisory"
],
"source": "PSIRT@rockwellautomation.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"description": [
{
"lang": "en",
"value": "CWE-286"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers."
},
{
"lang": "es",
"value": "Existe un problema de seguridad en FactoryTalk Linx Network Browser. Al modificar process.env.NODE_ENV a \"development\", el atacante puede deshabilitar la validación del token FTSP. Esta omisión permite el acceso para crear, actualizar y eliminar controladores FTLinx."
}
],
"lastModified": "2026-06-17T10:06:04.210",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "23BAB4E2-83AE-4C44-AE27-BFCF753D9BB5",
"versionEndExcluding": "6.50"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com"
}