CVE-2025-7674
Improper Input Validation vulnerability in Roche Diagnostics navify Monitoring allows an attacker to manipulate input data, which may lead to a denial of service (DoS) due to negatively impacting the server's performance. This vulnerability has no impact on data confidentiality or integrity. This issue affects navify Monitoring before 1.08.00.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:Y/R:U/V:D/RE:M/U:Green
- Puntuación base: 7.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.28%
- Percentil entre todas las CVEs puntuadas: 18
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1499Endpoint Denial of Serviceimpact80 %
Vector CVSS indica acceso remoto autenticado (AV:N, PR:L) sin interacción; CWE-20 de validación de entrada; impacto VA:H (disponibilidad) sugiere DoS. T1210 por servicios remotos; T1499 por negación de servicio explícita.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-20
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-7674",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-7674",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-08-05T20:32:26.480959Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "5cdcf916-2b10-4ec8-bfc1-d054821e439e",
"cvssData": {
"Safety": "NEGLIGIBLE",
"version": "4.0",
"Recovery": "USER",
"baseScore": 7.1,
"Automatable": "YES",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:Y/R:U/V:D/RE:M/U:Green",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "GREEN",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "MODERATE",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "5cdcf916-2b10-4ec8-bfc1-d054821e439e",
"affectedData": [
{
"vendor": "Roche Diagnostics",
"product": "navify Monitoring",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.08.00",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-08-05T17:15:29.700",
"references": [
{
"url": "https://preview-owp.roche.com/content/dam/diagnostics/Blueprint/en/pdf/navify%20Monitoring%20-%20API%20Input%20Validation%20Vulnerability%20-%20Product%20Security%20Advisory.pdf",
"source": "5cdcf916-2b10-4ec8-bfc1-d054821e439e"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "5cdcf916-2b10-4ec8-bfc1-d054821e439e",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Input Validation vulnerability in Roche Diagnostics navify Monitoring allows an attacker to manipulate input data, which may lead to a denial of service (DoS) due to negatively impacting the server's performance. This vulnerability has no impact on data confidentiality or integrity.\nThis issue affects navify Monitoring before 1.08.00."
},
{
"lang": "es",
"value": "Una vulnerabilidad de validación de entrada incorrecta en navify Monitoring de Roche Diagnostics permite a un atacante manipular los datos de entrada, lo que puede provocar una denegación de servicio (DoS) al afectar negativamente al rendimiento del servidor. Esta vulnerabilidad no afecta la confidencialidad ni la integridad de los datos. Este problema afecta a navify Monitoring antes de la versión 1.08.00."
}
],
"lastModified": "2026-06-17T10:05:27.070",
"sourceIdentifier": "5cdcf916-2b10-4ec8-bfc1-d054821e439e"
}