« Volver al listado

CVE-2025-7376

Estado: AplazadaMedia (5.9)—

Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS version 11.00, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, and Mitsubishi Electric Iconics Digital Solutions GENESIS version 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the processes of the affected products to a target file.

Leer descripción completaMostrar menos

This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (8)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-7376",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-7376",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-08-07T14:11:34.071248Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 5.9,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 4,
        "exploitabilityScore": 1.5
      }
    ]
  },
  "affected": [
    {
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "affectedData": [
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "GENESIS64",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "product": "GENESIS64",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "ICONICS Suite",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "product": "ICONICS Suite",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "MobileHMI",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "product": "MobileHMI",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "Hyper Historian",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "product": "Hyper Historian",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "AnalytiX",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "product": "AnalytiX",
          "versions": [
            {
              "status": "affected",
              "version": "versions 10.97.3 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "IoTWorX",
          "versions": [
            {
              "status": "affected",
              "version": "version 10.95"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "product": "IoTWorX",
          "versions": [
            {
              "status": "affected",
              "version": "version 10.95"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "MC Works64",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Corporation",
          "product": "GENESIS",
          "versions": [
            {
              "status": "affected",
              "version": "version 11.00"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Mitsubishi Electric Iconics Digital Solutions",
          "product": "GENESIS",
          "versions": [
            {
              "status": "affected",
              "version": "version 11.00"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-08-06T07:15:34.100",
  "references": [
    {
      "url": "https://jvn.jp/vu/JVNVU96364629",
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
    },
    {
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-217-01",
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
    },
    {
      "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-009_en.pdf",
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "description": [
        {
          "lang": "en",
          "value": "CWE-64"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric GENESIS version 11.00, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95, and Mitsubishi Electric Iconics Digital Solutions GENESIS version 11.00 allows a local authenticated attacker to make an unauthorized write to arbitrary files, by creating a symbolic link from a file used as a write destination by the processes of the affected products to a target file. This could allow the attacker to destroy the file on a PC with the affected products installed, resulting in a denial-of-service (DoS) condition on the PC if the destroyed file is necessary for the operation of the PC."
    },
    {
      "lang": "es",
      "value": "La vulnerabilidad de acceso directo de Windows (.LNK) en varios procesos de Mitsubishi Electric Iconics Digital Solutions GENESIS64 (todas las versiones), Mitsubishi Electric Iconics Digital Solutions GENESIS (versión 11.00), Mitsubishi Electric GENESIS64 (todas las versiones), Mitsubishi Electric MC Works64 (todas las versiones) y Mitsubishi Electric GENESIS (versión 11.00) permite a un atacante local autenticado realizar escrituras no autorizadas en archivos arbitrarios mediante la creación de un enlace simbólico desde un archivo utilizado como destino de escritura por los procesos de los productos afectados a un archivo de destino. Esto podría permitir al atacante destruir el archivo en un PC con los productos afectados instalados, lo que provocaría una denegación de servicio (DoS) en el PC si el archivo destruido es necesario para su funcionamiento."
    }
  ],
  "lastModified": "2026-06-17T10:04:48.483",
  "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"
}