CVE-2025-63835
A stack-based buffer overflow vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the guestSsid parameter of the /goform/WifiGuestSet interface. Remote attackers can exploit this vulnerability by sending oversized data to the guestSsid parameter, leading to denial of service (device crash) or potential remote code execution.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.65%
- Percentil entre todas las CVEs puntuadas: 49
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1059Command and Scripting Interpreterexecution75 % - Impacto secundario
T1499.004Application or System Exploitationimpact80 %
Vector CVSS con PR:L (privilegios locales requeridos) y acceso remoto (AV:N) indica T1210. Buffer overflow permite ejecución de código (T1059) o DoS (T1499.004 por crash del dispositivo).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-787
- CWE-121
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-63835",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-63835",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-11-18T16:31:32.213718Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2025-11-10T17:15:35.960",
"references": [
{
"url": "https://github.com/babraink/cve_report/blob/main/cve_report/tenda/tendaAC18/2_wifiguest_guestssid_overflow/README.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stack-based buffer overflow vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the guestSsid parameter of the /goform/WifiGuestSet interface. Remote attackers can exploit this vulnerability by sending oversized data to the guestSsid parameter, leading to denial of service (device crash) or potential remote code execution."
},
{
"lang": "es",
"value": "Una vulnerabilidad de desbordamiento de búfer basado en pila fue descubierta en Tenda AC18 v15.03.05.05_multi. La vulnerabilidad existe en el parámetro guestSsid de la interfaz /goform/WifiGuestSet. Atacantes remotos pueden explotar esta vulnerabilidad enviando datos de tamaño excesivo al parámetro guestSsid, lo que lleva a una denegación de servicio (caída del dispositivo) o a una potencial ejecución remota de código."
}
],
"lastModified": "2026-06-17T09:53:31.340",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "4D5CB727-FC6B-4212-A61E-2888A0DADFB0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}