CVE-2025-6377
A remote code execution security issue exists in the Rockwell Automation Arena®. A crafted DOE file can force Arena Simulation to write beyond the boundaries of an allocated object. Exploitation requires user interaction, such as opening a malicious file within the software. If exploited, a threat actor could execute arbitrary code on the target system. The software must run under the context of the administrator in order to cause worse case impact. This is reflected in the Rockwell CVSS score, as AT:P.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.22%
- Percentil entre todas las CVEs puntuadas: 12
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution90 % - Impacto principal
T1059Command and Scripting Interpreterexecution85 %
Vector CVSS con UI:A (interacción del usuario) y AV:L (acceso local): requiere abrir archivo malicioso DOE. RCE directo en contexto administrador tras explotación de desbordamiento de búfer (CWE-787).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-20
- CWE-787
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-6377",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-6377",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-07-09T20:37:33.961481Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.1,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "ACTIVE",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "PSIRT@rockwellautomation.com",
"affectedData": [
{
"vendor": "Rockwell Automation",
"product": "Arena®",
"versions": [
{
"status": "affected",
"version": "<=16.20.08"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-07-09T21:15:28.620",
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1729.html",
"tags": [
"Vendor Advisory"
],
"source": "PSIRT@rockwellautomation.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A remote\ncode execution security issue exists in the Rockwell Automation Arena®. A crafted DOE\nfile can force Arena Simulation to write beyond the boundaries of an allocated\nobject. Exploitation\nrequires user interaction, such as opening a malicious file within the software.\nIf exploited, a threat actor could execute arbitrary code on the target system.\nThe software must run under the context of the administrator in order to cause\nworse case impact. This is reflected in the Rockwell CVSS score, as AT:P."
},
{
"lang": "es",
"value": "Existe un problema de seguridad de ejecución remota de código en Rockwell Automation Arena®. Un archivo DOE manipulado puede obligar a Arena Simulation a escribir más allá de los límites de un objeto asignado. Su explotación requiere la interacción del usuario, como abrir un archivo malicioso dentro del software. Si se explota, un atacante podría ejecutar código arbitrario en el sistema objetivo. El software debe ejecutarse bajo el contexto del administrador para causar un impacto aún mayor. Esto se refleja en la puntuación CVSS de Rockwell, como AT:P."
}
],
"lastModified": "2026-06-17T10:01:45.683",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:arena:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B1CA47BE-FC9B-41AE-B939-C8FF636596A6",
"versionEndExcluding": "16.20.09"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com"
}