« Volver al listado

CVE-2025-63210

Estado: AnalizadaCrítica (9.8)—

The Newtec Celox UHD (models: CELOXA504, CELOXA820) running firmware version celox-21.6.13 is vulnerable to an authentication bypass. An attacker can exploit this issue by modifying intercepted responses from the /celoxservice endpoint. By injecting a forged response body during the loginWithUserName flow, the attacker can gain Superuser or Operator access without providing valid credentials.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

AV:N/PR:N sin UI indica red sin autenticación → T1190. Acceso sin credenciales válidas mediante inyección de respuesta → T1078. Modificación de respuestas autentica usuario falso → T1565.001 secundario.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-63210",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-63210",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-11-19T18:20:45.785196Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2025-11-19T18:15:49.207",
  "references": [
    {
      "url": "https://github.com/shiky8/my--cve-vulnerability-research/tree/main/CVE-2025-63210_Newtec%20Celox%20UHD%20Authentication%20Bypass%20_%20Privilege%20Escalation",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.newtec.com/",
      "tags": [
        "Product"
      ],
      "source": "cve@mitre.org"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        },
        {
          "lang": "en",
          "value": "CWE-302"
        },
        {
          "lang": "en",
          "value": "CWE-303"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "The Newtec Celox UHD (models: CELOXA504, CELOXA820) running firmware version celox-21.6.13 is vulnerable to an authentication bypass. An attacker can exploit this issue by modifying intercepted responses from the /celoxservice endpoint. By injecting a forged response body during the loginWithUserName flow, the attacker can gain Superuser or Operator access without providing valid credentials."
    }
  ],
  "lastModified": "2026-06-17T09:52:56.620",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:newtec:celoxa504_firmware:celox-21.6.13:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "EA556A8D-5972-437C-9A37-FC4F2B656267"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:newtec:celoxa504:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F677853F-1185-4595-AB38-D753C8D3B823"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:newtec:celoxa820_firmware:celox-21.6.13:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3AF7F111-E205-440D-9666-1C56A879B98C"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:newtec:celoxa820:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4BB5D883-F946-43D3-80B1-5642EFA921AB"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}