CVE-2025-59787
Estado: AnalizadaMedia (5.3)—
2N Access Commander application version 3.4.2 and prior returns HTTP 500 Internal Server Error responses when receiving malformed or manipulated requests, indicating improper handling of invalid input and potential security or availability impacts.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.20%
- Percentil entre todas las CVEs puntuadas: 9
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-703
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-59787",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-59787",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-03-05T19:00:54.958469Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 2.5,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "be69f613-e5f6-419b-800c-30351aa8933c",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.3,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "be69f613-e5f6-419b-800c-30351aa8933c",
"affectedData": [
{
"vendor": "2N Telekomunikace a.s.",
"product": "2N Access Commander",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "3.5",
"versionType": "Release"
}
],
"platforms": [
"Linux"
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-03-04T16:16:25.633",
"references": [
{
"url": "https://www.2n.com/en-GB/download/cve_2025_59787_acom_3_5_v1pdf",
"tags": [
"Vendor Advisory"
],
"source": "be69f613-e5f6-419b-800c-30351aa8933c"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "be69f613-e5f6-419b-800c-30351aa8933c",
"description": [
{
"lang": "en",
"value": "CWE-703"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "2N Access Commander application version 3.4.2 and prior returns HTTP 500 Internal Server Error responses when receiving malformed or manipulated requests, indicating improper handling of invalid input and potential security or availability impacts."
},
{
"lang": "es",
"value": "La aplicación 2N Access Commander versión 3.4.2 y anteriores devuelve respuestas de error interno del servidor HTTP 500 al recibir solicitudes malformadas o manipuladas, lo que indica un manejo inadecuado de entrada inválida y posibles impactos en la seguridad o disponibilidad."
}
],
"lastModified": "2026-06-17T09:46:43.073",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:2n:access_commander:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F5E0C7F3-83DD-4DC1-A519-51626A3E6F85",
"versionEndExcluding": "3.5"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "be69f613-e5f6-419b-800c-30351aa8933c"
}