« Volver al listado

CVE-2025-5946

Estado: AnalizadaAlta (7.2)—

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.

This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

CWE-78 (OS Command Injection) en servicio remoto Centreon con PR:H indica explotación de servicio remoto por usuario autenticado (T1210). El impacto es ejecución de comandos arbitrarios en el servidor mediante inyección en parámetro 'poller reload'.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-5946",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-5946",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-10-14T16:03:02.831678Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ]
  },
  "affected": [
    {
      "source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
      "affectedData": [
        {
          "vendor": "Centreon",
          "modules": [
            "Poller reload setup in the configuration"
          ],
          "product": "Infra Monitoring",
          "versions": [
            {
              "status": "affected",
              "version": "24.10.0",
              "lessThan": "24.10.13",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "24.04.0",
              "lessThan": "24.04.18",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "23.10.0",
              "lessThan": "23.10.28",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-10-14T15:16:11.967",
  "references": [
    {
      "url": "https://github.com/centreon/centreon/releases",
      "tags": [
        "Release Notes"
      ],
      "source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7"
    },
    {
      "url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5946-centreon-web-all-versions-high-severity-5104",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection.\nOn the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
    }
  ],
  "lastModified": "2026-06-17T09:49:04.983",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "52CE7EB8-492F-4469-9E01-8C63144D785F",
              "versionEndExcluding": "23.10.28",
              "versionStartIncluding": "23.10.0"
            },
            {
              "criteria": "cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7C3C1C61-F2EB-4900-9BB7-C80A6C538E5E",
              "versionEndExcluding": "24.04.18",
              "versionStartIncluding": "24.04.0"
            },
            {
              "criteria": "cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "09800EB4-10FC-4667-9FC8-88D9A8BB2751",
              "versionEndExcluding": "24.10.13",
              "versionStartIncluding": "24.10.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7"
}