CVE-2025-5946
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.
This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 14%
- Percentil entre todas las CVEs puntuadas: 96
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 %
CWE-78 (OS Command Injection) en servicio remoto Centreon con PR:H indica explotación de servicio remoto por usuario autenticado (T1210). El impacto es ejecución de comandos arbitrarios en el servidor mediante inyección en parámetro 'poller reload'.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-5946",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-5946",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-10-14T16:03:02.831678Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
"affectedData": [
{
"vendor": "Centreon",
"modules": [
"Poller reload setup in the configuration"
],
"product": "Infra Monitoring",
"versions": [
{
"status": "affected",
"version": "24.10.0",
"lessThan": "24.10.13",
"versionType": "custom"
},
{
"status": "affected",
"version": "24.04.0",
"lessThan": "24.04.18",
"versionType": "custom"
},
{
"status": "affected",
"version": "23.10.0",
"lessThan": "23.10.28",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-10-14T15:16:11.967",
"references": [
{
"url": "https://github.com/centreon/centreon/releases",
"tags": [
"Release Notes"
],
"source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7"
},
{
"url": "https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5946-centreon-web-all-versions-high-severity-5104",
"tags": [
"Vendor Advisory"
],
"source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection.\nOn the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.\n\nThis issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28."
}
],
"lastModified": "2026-06-17T09:49:04.983",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "52CE7EB8-492F-4469-9E01-8C63144D785F",
"versionEndExcluding": "23.10.28",
"versionStartIncluding": "23.10.0"
},
{
"criteria": "cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7C3C1C61-F2EB-4900-9BB7-C80A6C538E5E",
"versionEndExcluding": "24.04.18",
"versionStartIncluding": "24.04.0"
},
{
"criteria": "cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "09800EB4-10FC-4667-9FC8-88D9A8BB2751",
"versionEndExcluding": "24.10.13",
"versionStartIncluding": "24.10.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "bd4443e6-1eef-43f3-9886-25fc9ceeaae7"
}