CVE-2025-59111
Estado: ModificadaMedia (6.9)—
Windu CMS is vulnerable to Broken Access Control in user editing functionality. Malicious attacker can send a GET request which allows privileged users to delete Super Admins which is not possible with GUI.
Only version 4.1 was tested and confirmed as vulnerable. This issue was fixed in version 4.1 build 2250.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 6.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.29%
- Percentil entre todas las CVEs puntuadas: 20
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-863
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-59111",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-59111",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-11-18T15:31:56.660563Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "NONE"
},
"impactScore": 5.2,
"exploitabilityScore": 1.2
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cvd@cert.pl",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 6.9,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "HIGH",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cvd@cert.pl",
"affectedData": [
{
"vendor": "JCD",
"product": "Windu CMS",
"versions": [
{
"status": "affected",
"changes": [
{
"at": "build 2250",
"status": "unaffected"
}
],
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "4.1"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-11-18T15:16:32.900",
"references": [
{
"url": "https://cert.pl/posts/2025/11/CVE-2025-59110",
"tags": [
"Third Party Advisory"
],
"source": "cvd@cert.pl"
},
{
"url": "https://windu.org",
"tags": [
"Product"
],
"source": "cvd@cert.pl"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cvd@cert.pl",
"description": [
{
"lang": "en",
"value": "CWE-863"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Windu CMS is vulnerable to Broken Access Control in user editing functionality. Malicious attacker can send a GET request which allows privileged users to delete Super Admins which is not possible with GUI.\n\nOnly version 4.1 was tested and confirmed as vulnerable.\nThis issue was fixed in version 4.1 build 2250."
}
],
"lastModified": "2026-06-17T09:45:34.387",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:windu:windu_cms:4.1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "614EBC19-889B-4FC0-8937-C52F415D4835"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cvd@cert.pl"
}