CVE-2025-5824
Autel MaxiCharger AC Wallbox Commercial Origin Validation Error Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Wallbox Commercial. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.
The specific flaw exists within the handling of bluetooth pairing requests. The issue results from insufficient validation of the origin of commands. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-26353.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.17%
- Percentil entre todas las CVEs puntuadas: 6
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1078Valid Accountsstealth · persistence · privilege escalation · initial access80 %
AV:A requiere red adyacente; CWE-346 indica validación insuficiente del origen; bypass de autenticación Bluetooth permite acceso no autorizado al sistema sin credenciales legítimas.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (9)
CWE
- CWE-346
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-5824",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-5824",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-06-25T18:21:18.194673Z"
}
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 1.6
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.6
}
]
},
"affected": [
{
"source": "zdi-disclosures@trendmicro.com",
"affectedData": [
{
"vendor": "Autel",
"product": "Autel MaxiCharger AC Wallbox Commercial",
"versions": [
{
"status": "affected",
"version": "1.36.00"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-06-25T18:15:23.173",
"references": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-25-343/",
"tags": [
"Third Party Advisory"
],
"source": "zdi-disclosures@trendmicro.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"description": [
{
"lang": "en",
"value": "CWE-346"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Autel MaxiCharger AC Wallbox Commercial Origin Validation Error Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Wallbox Commercial. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the handling of bluetooth pairing requests. The issue results from insufficient validation of the origin of commands. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-26353."
},
{
"lang": "es",
"value": "Vulnerabilidad de omisión de autenticación por error de validación de origen en Autel MaxiCharger AC Wallbox Commercial. Esta vulnerabilidad permite a atacantes adyacentes a la red omitir la autenticación en las instalaciones afectadas de Autel MaxiCharger AC Wallbox Commercial. Para explotar esta vulnerabilidad, un atacante debe primero emparejar un dispositivo Bluetooth malicioso con el sistema objetivo. La falla específica se encuentra en la gestión de solicitudes de emparejamiento Bluetooth. El problema se debe a una validación insuficiente del origen de los comandos. Un atacante puede aprovechar esta vulnerabilidad para omitir la autenticación en el sistema. Anteriormente, se conocía como ZDI-CAN-26353."
}
],
"lastModified": "2026-06-17T09:48:49.130",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "0C17A950-221C-41E3-9BE3-31736CE4516F",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "42F0DDFA-A1B9-4EC2-8F43-3261F9BCE814",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_ac_elite_business_c50:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "5B2F9001-71B7-4B39-9114-FC54F4EAE9E7"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_pro_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "9471EA48-BD48-40AA-8FF7-28503D04D1F0",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_pro_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "72FB45A6-E876-45A6-A39F-4E0B28620A71",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_ac_pro:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "92CF3B40-B18F-4C4D-8A6C-68A8B1F288AE"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_ultra_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "55C717AF-39F9-4080-AE56-7511E0F62F79",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_ac_ultra_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "7AFD91E7-E581-451B-AB15-099AA7A4F611",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_ac_ultra:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CDC6E5EB-C4D4-4488-B01B-C0E568FCA0D1"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_compact_mobile_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "2C9AEB54-FFBC-4B24-AC7B-1B5F3CC762DF",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_compact_mobile_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "BBFCD8D0-53E7-4B06-B763-36381E13DD26",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dc_compact_mobile:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "52578631-C18D-4244-9377-AB787EDE08A1"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_compact_pedestal_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "FED7B2BF-5D38-4393-9986-588407A3476D",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_compact_pedestal_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "3244FD64-1714-4597-BA66-CC5FC8D514FF",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dc_compact_pedestal:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "ED75BBD9-D889-49D3-95B0-EF6F15B65E10"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_fast_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "264E7F9D-0603-43C9-B7A9-6A35EA8F0063",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_fast_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "E5F4FE58-5AA6-45D0-AE48-959DA0CF53C8",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dc_fast:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6C8B42B3-3F66-426F-8FFE-993FCAA12EB4"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_hipower_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "E30E7592-29C4-4333-A02C-7468074BD104",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dc_hipower_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "F9058C73-831E-48BF-AE9B-19AB33F10F14",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dc_hipower:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "EE5DF603-DBD2-4AFF-AE3D-946277C2C6C2"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_dh480_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "33F4A529-54C4-4EBC-871E-5E0C71859F69",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_dh480_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "62718E33-B591-49D4-8CC6-057D6254873A",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_dh480:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CAD62E93-8613-48DF-9C42-B12655FE1680"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:autel:maxicharger_single_charger_firmware:*:*:*:*:*:*:*:american_standard",
"vulnerable": true,
"matchCriteriaId": "372D3478-67AA-4D41-908C-5CFE6CAA25A8",
"versionEndExcluding": "1.39.51"
},
{
"criteria": "cpe:2.3:o:autel:maxicharger_single_charger_firmware:*:*:*:*:*:*:*:european_standard",
"vulnerable": true,
"matchCriteriaId": "8ED07235-5610-4E80-8940-6EB942CC648C",
"versionEndExcluding": "1.56.51"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:autel:maxicharger_single_charger:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0E6B2074-D4A6-424F-B7C5-40A0FE5C17F8"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com"
}