CVE-2025-55705
This vulnerability occurs when the system permits multiple simultaneous connections to the backend using the same charging station ID. This can result in unauthorized access, data inconsistency, or potential manipulation of charging sessions. The lack of proper session management and expiration control allows attackers to exploit this weakness by reusing valid charging station IDs to establish multiple sessions concurrently.
CVSS
- Version: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Base score: 9.8
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.34%
- Percentile among all scored CVEs: 25
- Score date: 10/5/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
🎯 ATT&CK techniques
How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.
- Exploitation
T1190Exploit Public-Facing Applicationinitial access85 % - Primary impact
T1078Valid Accountsstealth · persistence · privilege escalation · initial access90 % - Secondary impact
T1005Data from Local Systemcollection70 % - Secondary impact
T1565.001Stored Data Manipulationimpact75 %
Acceso remoto sin autenticación (PR:N, UI:N) a aplicación expuesta; permite reutilizar IDs de estación para múltiples sesiones, obteniendo acceso no autorizado, manipulación de datos y lectura de información de sesiones.
Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.
🛡️ ATT&CK mitigations that cover these techniques
Affected technologies (1)
CWEs
- CWE-613
References
Raw JSON (NVD)
Show
{
"id": "CVE-2025-55705",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-55705",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-01-23T20:10:35.019479Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.3,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 3.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "EVMAPA",
"product": "EVMAPA",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-01-22T23:15:50.137",
"references": [
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-022-08.json",
"tags": [
"Third Party Advisory"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-022-08",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-613"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability occurs when the system permits multiple simultaneous \nconnections to the backend using the same charging station ID. This can \nresult in unauthorized access, data inconsistency, or potential \nmanipulation of charging sessions. The lack of proper session management\n and expiration control allows attackers to exploit this weakness by \nreusing valid charging station IDs to establish multiple sessions \nconcurrently."
},
{
"lang": "es",
"value": "Esta vulnerabilidad ocurre cuando el sistema permite múltiples conexiones simultáneas al backend utilizando el mismo ID de estación de carga. Esto puede resultar en acceso no autorizado, inconsistencia de datos o manipulación potencial de las sesiones de carga. La falta de una gestión de sesión y control de expiración adecuados permite a los atacantes explotar esta debilidad reutilizando IDs válidos de estaciones de carga para establecer múltiples sesiones concurrentemente."
}
],
"lastModified": "2026-06-17T09:42:05.733",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:evmapa:evmapa:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8C85ACDB-38D2-4466-9206-529F45F4720E"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}