« Volver al listado

CVE-2025-52578

Estado: AplazadaMedia (5.7)—

Incorrect Usage of Seeds in Pseudo-Random Number Generator (CWE- 335) vulnerability in the High Sec ELM may allow a sophisticated attacker with physical access, to compromise internal device communications.

This issue affects Command Centre Server:

9.30 prior to vCR9.30.251028a (distributed in 9.30.2881 (MR3)), 9.20 prior to vCR9.20.251028a (distributed in 9.20.3265 (MR5)), 9.10 prior to vCR9.10.251028a (distributed in 9.10.4135 (MR8)), all versions of 9.00 and prior.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-52578",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-52578",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-11-18T15:04:03.417918Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "disclosures@gallagher.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.7,
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 0.5
      }
    ]
  },
  "affected": [
    {
      "source": "disclosures@gallagher.com",
      "affectedData": [
        {
          "vendor": "Gallagher",
          "product": "High Sec End of Line Module",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "9.00"
            },
            {
              "status": "affected",
              "version": "9.30",
              "lessThan": "vCR9.30.251028a",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "9.20",
              "lessThan": "vCR9.20.251028a",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "9.10",
              "lessThan": "vCR9.10.251028a",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-11-18T04:15:44.330",
  "references": [
    {
      "url": "https://security.gallagher.com/en-NZ/Security-Advisories/CVE-2025-52578",
      "source": "disclosures@gallagher.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "disclosures@gallagher.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-335"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Incorrect Usage of Seeds in Pseudo-Random Number Generator (CWE- 335) vulnerability in the High Sec ELM may allow a sophisticated attacker with physical access, to compromise internal device communications.\n\nThis issue affects Command Centre Server: \n\n9.30 prior to vCR9.30.251028a (distributed in 9.30.2881 (MR3)), 9.20 prior to vCR9.20.251028a (distributed in 9.20.3265 (MR5)), 9.10 prior to vCR9.10.251028a (distributed in 9.10.4135 (MR8)), all versions of 9.00 and prior."
    }
  ],
  "lastModified": "2026-06-17T09:36:42.853",
  "sourceIdentifier": "disclosures@gallagher.com"
}