CVE-2025-50130
A heap-based buffer overflow vulnerability exists in VS6Sim.exe contained in V-SFT and TELLUS provided by FUJI ELECTRIC CO., LTD. Opening V9 files or X1 files specially crafted by an attacker on the affected product may lead to arbitrary code execution.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.21%
- Percentil entre todas las CVEs puntuadas: 11
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution85 % - Impacto principal
T1059Command and Scripting Interpreterexecution80 %
Vector CVSS con UI:A (requiere interacción del usuario) en acceso local (AV:L). Apertura de archivos V9/X1 preparados causa desbordamiento de búfer y ejecución arbitraria de código.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (2)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-122
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-50130",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-50130",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-07-08T13:33:13.788717Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "vultures@jpcert.or.jp",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "vultures@jpcert.or.jp",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.4,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "ACTIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "vultures@jpcert.or.jp",
"affectedData": [
{
"vendor": "FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd.",
"product": "V-SFT-6",
"versions": [
{
"status": "affected",
"version": "v6.2.5.0 and earlier"
}
]
},
{
"vendor": "FUJI ELECTRIC CO., LTD. / Hakko Electronics Co., Ltd.",
"product": "TELLUS",
"versions": [
{
"status": "affected",
"version": "v4.0.20.0 and earlier"
}
]
}
]
}
],
"published": "2025-07-08T13:15:33.710",
"references": [
{
"url": "https://jvn.jp/en/vu/JVNVU94011267/",
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/Search.php",
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://monitouch.fujielectric.com/site/download-e/09vsft6_inf/Search.php",
"source": "vultures@jpcert.or.jp"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "vultures@jpcert.or.jp",
"description": [
{
"lang": "en",
"value": "CWE-122"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A heap-based buffer overflow vulnerability exists in VS6Sim.exe contained in V-SFT and TELLUS provided by FUJI ELECTRIC CO., LTD.\r\nOpening V9 files or X1 files specially crafted by an attacker on the affected product may lead to arbitrary code execution."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de desbordamiento de búfer en el montón en VS6Sim.exe, incluido en V-SFT y TELLUS, proporcionados por FUJI ELECTRIC CO., LTD. Abrir archivos V9 o X1 especialmente manipulados por un atacante en el producto afectado puede provocar la ejecución de código arbitrario."
}
],
"lastModified": "2026-06-17T09:34:41.433",
"sourceIdentifier": "vultures@jpcert.or.jp"
}