CVE-2025-50122
A CWE-331: Insufficient Entropy vulnerability exists that could cause root password discovery when the password generation algorithm is reverse engineered with access to installation or upgrade artifacts.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.22%
- Percentil entre todas las CVEs puntuadas: 11
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement45 % - Impacto principal
T1078.001Default Accountsstealth · persistence · privilege escalation · initial access60 % - Impacto secundario
T1556.001Domain Controller Authenticationdefense impairment · persistence · credential access50 %
CWE-331 (entropía insuficiente) permite descubrir contraseña root mediante ingeniería inversa de artefactos; acceso red adyacente (AV:A) sugiere T1210. Impactos: obtención de credenciales válidas (T1078.001) y posible manipulación de autenticación (T1556.001).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
CWE
- CWE-331
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-50122",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-50122",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-07-11T15:08:21.649572Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.9,
"Automatable": "NOT_DEFINED",
"attackVector": "ADJACENT",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "EcoStruxure™ IT Data Center Expert",
"versions": [
{
"status": "affected",
"version": "8.3",
"versionType": "custom",
"lessThanOrEqual": "Prior to"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-07-11T10:15:23.333",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-189-01.pdf",
"source": "cybersecurity@se.com"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/7",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-331"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-331: Insufficient Entropy vulnerability exists that could cause root password discovery when the\npassword generation algorithm is reverse engineered with access to installation or upgrade artifacts."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad CWE-331: Entropía insuficiente que podría provocar el descubrimiento de la contraseña de root cuando el algoritmo de generación de contraseñas se somete a ingeniería inversa con acceso a artefactos de instalación o actualización."
}
],
"lastModified": "2026-06-17T09:34:40.513",
"sourceIdentifier": "cybersecurity@se.com"
}