CVE-2025-47418
Estado: AplazadaMedia (5.3)—
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.
There is no visible indication when the system is recording and recording can be enabled remotely via a network API. This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.43%
- Percentil entre todas las CVEs puntuadas: 35
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-200
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-47418",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-47418",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-05-07T13:46:13.710646Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.3,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"affectedData": [
{
"vendor": "Crestron",
"product": "Automate VX",
"versions": [
{
"status": "affected",
"changes": [
{
"at": "6.4.1.8",
"status": "unaffected"
}
],
"version": "5.6.8161.21536",
"versionType": "custom",
"lessThanOrEqual": "6.4.0.49"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-05-06T21:16:20.737",
"references": [
{
"url": "https://security.crestron.com/",
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3"
},
{
"url": "https://www.crestron.com/Software-Firmware/Software/Automate-VX-Software/6-4-1-8",
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3"
},
{
"url": "https://www.crestron.com/release_notes/automate_vx_6.4.1.8_release_notes.pdf",
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.\n\nThere is no visible indication when the system is recording and recording can be enabled remotely via a network API. \nThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49."
},
{
"lang": "es",
"value": "La vulnerabilidad de exposición de información confidencial a un agente no autorizado en Crestron Automate VX permite el uso indebido de la funcionalidad. No hay ninguna indicación visible cuando el sistema está grabando, y la grabación se puede habilitar remotamente mediante una API de red. Este problema afecta a Automate VX desde la versión 5.6.8161.21536 hasta la 6.4.0.49."
}
],
"lastModified": "2026-06-17T09:28:05.423",
"sourceIdentifier": "25b0b659-c4b4-483f-aecb-067757d23ef3"
}