CVE-2025-46626
Reuse of a static AES key and initialization vector for encrypted traffic to the 'ate' management service of the Tenda RX2 Pro 16.03.30.14 allows an attacker to decrypt, replay, and/or forge traffic to the service.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
- Puntuación base: 7.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.23%
- Percentil entre todas las CVEs puntuadas: 13
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access85 % - Impacto principal
T1005Data from Local Systemcollection75 % - Impacto secundario
T1550.001Application Access Tokenlateral movement65 % - Impacto secundario
T1565.001Stored Data Manipulationimpact70 %
Vulnerabilidad en servicio expuesto en red (management service remoto, AV:N/PR:N). Impactos: lectura de tráfico cifrado (T1005), falsificación de comandos (T1565.001), replay de sesiones (T1550.001). CWE-326 (criptografía débil) sustenta acceso a datos sensibles.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-326
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-46626",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-46626",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-05-02T15:16:19.130569Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.3,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2025-05-01T20:15:38.190",
"references": [
{
"url": "https://blog.uturn.dev/#/writeups/iot-village/tenda-rx2pro/README?id=cve-2025-46625-command-injection-through-setlancfg-in-httpd",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.tendacn.com/us/default.html",
"tags": [
"Product"
],
"source": "cve@mitre.org"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-326"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Reuse of a static AES key and initialization vector for encrypted traffic to the 'ate' management service of the Tenda RX2 Pro 16.03.30.14 allows an attacker to decrypt, replay, and/or forge traffic to the service."
},
{
"lang": "es",
"value": "La reutilización de una clave AES estática y un vector de inicialización para el tráfico cifrado hacia el servicio de gestión 'ate' del Tenda RX2 Pro 16.03.30.14 permite a un atacante descifrar, reproducir y/o falsificar el tráfico hacia el servicio."
}
],
"lastModified": "2026-06-17T09:26:43.713",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:rx2_pro_firmware:16.03.30.14:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A6C6559F-BD91-44DF-BA9E-2F55C714009C"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:rx2_pro:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E95CB932-CDB6-4E44-A868-5DEEAD982F7C"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}