« Volver al listado

CVE-2025-4395

Estado: AplazadaMedia (6.8)—

Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality.

This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-4395",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-4395",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-07-24T13:18:46.616820Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "security@medtronic.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.8,
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 0.9
      }
    ]
  },
  "affected": [
    {
      "source": "security@medtronic.com",
      "affectedData": [
        {
          "vendor": "Medtronic",
          "product": "MyCareLink Patient Monitor 24950",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "June 25, 2025",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Medtronic",
          "product": "MyCareLink Patient Monitor 24952",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "June 25, 2025",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-07-24T07:15:53.660",
  "references": [
    {
      "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-205-01",
      "source": "security@medtronic.com"
    },
    {
      "url": "https://www.medtronic.com/en-us/e/product-security/security-bulletins/mycarelink-patient-monitor-vulnerabilities.html",
      "source": "security@medtronic.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "security@medtronic.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-258"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality. \n\nThis issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025"
    },
    {
      "lang": "es",
      "value": "Medtronic MyCareLink Patient Monitor tiene una cuenta de usuario integrada con una contraseña vacía, lo que permite a un atacante con acceso físico iniciar sesión sin contraseña y modificar las funciones del sistema. Este problema afecta a los modelos 24950 y 24952 deMedtronic MyCareLink Patient Monitor antes del 25 de junio de 2025."
    }
  ],
  "lastModified": "2026-06-17T09:33:10.940",
  "sourceIdentifier": "security@medtronic.com"
}