CVE-2025-43484
Estado: AnalizadaMedia (6)—
A potential reflected cross-site scripting vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The website does not validate or sanitize the user input before rendering it in the response. HP has addressed the issue in the latest software update.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 6
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.19%
- Percentil entre todas las CVEs puntuadas: 8
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-43484",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-43484",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-07-23T20:11:34.526319Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 6.1,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "hp-security-alert@hp.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 6,
"Automatable": "NOT_DEFINED",
"attackVector": "ADJACENT",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "hp-security-alert@hp.com",
"affectedData": [
{
"vendor": "HP Inc.",
"product": "Poly Clariti Manager",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-07-23T00:15:24.953",
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037",
"tags": [
"Vendor Advisory"
],
"source": "hp-security-alert@hp.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "hp-security-alert@hp.com",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential reflected cross-site scripting vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nwebsite does not validate or sanitize the user input before rendering it in the\nresponse. HP has addressed the issue in the latest software update."
},
{
"lang": "es",
"value": "Se ha identificado una posible vulnerabilidad de cross-site scripting reflejado en Poly Clariti Manager para versiones anteriores a la 10.12.1. El sitio web no valida ni depura la entrada del usuario antes de mostrarla en la respuesta. HP ha solucionado el problema en la última actualización de software."
}
],
"lastModified": "2026-06-17T09:24:06.723",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hp:poly_clariti_manager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "82C289E5-06F3-48F9-8C75-6CCFE4686F5C",
"versionEndExcluding": "10.12.2"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "hp-security-alert@hp.com"
}