CVE-2025-43022
A potential SQL injection vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow a privileged user to execute SQL commands. HP has addressed the issue in the latest software update.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.32%
- Percentil entre todas las CVEs puntuadas: 23
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1005Data from Local Systemcollection80 % - Impacto secundario
T1565.001Stored Data Manipulationimpact75 %
AV:A + PR:H sugieren acceso de red adyacente con alto privilegio; CWE-89 (SQL injection) permite lectura (T1005) y manipulación de datos (T1565.001) en BD.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-89
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-43022",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-43022",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-07-23T20:10:21.143873Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "hp-security-alert@hp.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.3,
"Automatable": "NOT_DEFINED",
"attackVector": "ADJACENT",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "HIGH",
"subIntegrityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "hp-security-alert@hp.com",
"affectedData": [
{
"vendor": "HP Inc.",
"product": "Poly Clariti Manager",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-07-22T23:15:24.810",
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037",
"tags": [
"Vendor Advisory"
],
"source": "hp-security-alert@hp.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "hp-security-alert@hp.com",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential SQL injection vulnerability has been identified in the Poly\nClariti Manager for versions prior to 10.12.1. The vulnerability could allow\na privileged user to execute SQL commands. HP has addressed the issue in\nthe latest software update."
},
{
"lang": "es",
"value": "Se ha identificado una posible vulnerabilidad de inyección SQL en Poly Clariti Manager para versiones anteriores a la 10.12.1. Esta vulnerabilidad podría permitir que un usuario con privilegios ejecute comandos SQL. HP ha solucionado el problema en la última actualización de software."
}
],
"lastModified": "2026-06-17T09:23:25.360",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hp:poly_clariti_manager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "82C289E5-06F3-48F9-8C75-6CCFE4686F5C",
"versionEndExcluding": "10.12.2"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "hp-security-alert@hp.com"
}