CVE-2025-41664
A low-privileged remote attacker could gain unauthorized access to critical resources, such as firmware and certificates, due to improper permission handling during the runtime of services (e.g., FTP/SFTP). This access could allow the attacker to escalate privileges and modify firmware.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.24%
- Percentil entre todas las CVEs puntuadas: 14
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1222File and Directory Permissions Modificationdefense impairment90 % - Impacto secundario
T1068Exploitation for Privilege Escalationprivilege escalation80 % - Impacto secundario
T1565.001Stored Data Manipulationimpact75 %
Vector CVSS AV:N/PR:L indica explotación remota con privilegios bajos (T1210). CWE-732 (permisos impropiamente configurados) permite acceder a firmware y certificados (T1222), escalar privilegios (T1068) y modificar firmware (manipulación de datos T1565.001).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
CWE
- CWE-732
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-41664",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-41664",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-09-08T16:02:34.291705Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.6
}
]
},
"affected": [
{
"source": "info@cert.vde.com",
"affectedData": [
{
"vendor": "WAGO",
"product": "Coupler 0750-0362",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "FW13",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "WAGO",
"product": "Coupler 0750-0362/0000-0001",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "FW13",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "WAGO",
"product": "Coupler 0750-0362/0040-0000",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "FW13",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "WAGO",
"product": "Coupler 0750-0362/K013-1080",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "FW13",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "WAGO",
"product": "Coupler 0750-0362/K019-7576",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "FW13",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "WAGO",
"product": "Coupler 0750-0363",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "FW13",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "WAGO",
"product": "Coupler 0750-0363/0040-0000",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "FW13",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "WAGO",
"product": "Coupler 0750-0364/0040-0010",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "FW13",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "WAGO",
"product": "Coupler 0750-0365/0040-0010",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "FW13",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "WAGO",
"product": "Coupler 0750-0366",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "FW13",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-09-08T07:15:36.013",
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-048",
"source": "info@cert.vde.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"description": [
{
"lang": "en",
"value": "CWE-732"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A low-privileged remote attacker could gain unauthorized access to critical resources, such as firmware and certificates, due to improper permission handling during the runtime of services (e.g., FTP/SFTP). This access could allow the attacker to escalate privileges and modify firmware."
}
],
"lastModified": "2026-06-17T09:22:55.230",
"sourceIdentifier": "info@cert.vde.com"
}