CVE-2025-41257
Estado: Pendiente de análisisMedia (4.8)—
Suprema’s BioStar 2 in version 2.9.11.6 allows users to set new password without providing the current one. Exploiting this flaw combined with other vulnerabilities can lead to unauthorized account access and potential system compromise.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N
- Puntuación base: 4.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.25%
- Percentil entre todas las CVEs puntuadas: 15
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-20
Referencias
- https://github.com/sbaresearch/advisories/tree/public/2025/SBA-ADV-20251104-02_Suprema_BioStar_2_Insecure_Password_Change
- https://www.supremainc.com/en/platform/hybrid-security-platform-biostar-2.asp
- https://github.com/sbaresearch/advisories/tree/public/2025/SBA-ADV-20251104-02_Suprema_BioStar_2_Insecure_Password_Change
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-41257",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-41257",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-03-09T20:59:23.621480Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "1e3a9e0f-5156-4bf8-b8a3-cc311bfc0f4a",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.8,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 2.5,
"exploitabilityScore": 2.2
}
]
},
"affected": [
{
"source": "1e3a9e0f-5156-4bf8-b8a3-cc311bfc0f4a",
"affectedData": [
{
"vendor": "Suprema",
"product": "BioStar 2",
"versions": [
{
"status": "affected",
"version": "2.9.11.6"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2026-03-04T23:16:09.713",
"references": [
{
"url": "https://github.com/sbaresearch/advisories/tree/public/2025/SBA-ADV-20251104-02_Suprema_BioStar_2_Insecure_Password_Change",
"source": "1e3a9e0f-5156-4bf8-b8a3-cc311bfc0f4a"
},
{
"url": "https://www.supremainc.com/en/platform/hybrid-security-platform-biostar-2.asp",
"source": "1e3a9e0f-5156-4bf8-b8a3-cc311bfc0f4a"
},
{
"url": "https://github.com/sbaresearch/advisories/tree/public/2025/SBA-ADV-20251104-02_Suprema_BioStar_2_Insecure_Password_Change",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"type": "Secondary",
"source": "1e3a9e0f-5156-4bf8-b8a3-cc311bfc0f4a",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Suprema’s BioStar 2 in version 2.9.11.6 allows users to set new password without providing the current one. Exploiting this flaw combined with other vulnerabilities can lead to unauthorized account access and potential system compromise."
},
{
"lang": "es",
"value": "BioStar 2 de Suprema en la versión 2.9.11.6 permite a los usuarios establecer una nueva contraseña sin proporcionar la actual. Explotar esta falla combinado con otras vulnerabilidades puede llevar a un acceso no autorizado a la cuenta y un posible compromiso del sistema."
}
],
"lastModified": "2026-06-17T09:22:41.130",
"sourceIdentifier": "1e3a9e0f-5156-4bf8-b8a3-cc311bfc0f4a"
}