« Volver al listado

CVE-2025-40838

Estado: AnalizadaMedia (5.1)—

Ericsson Indoor Connect 8855 contains a vulnerability where server-side security can be bypassed in the client which if exploited can lead to unauthorized disclosure of certain information.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-40838",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-40838",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-09-25T15:44:16.433331Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 5.1,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "HIGH",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "LOW",
          "vulnConfidentialityImpact": "NONE",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf",
      "affectedData": [
        {
          "vendor": "Ericsson",
          "product": "Indoor Connect 8855",
          "versions": [
            {
              "status": "affected",
              "changes": [
                {
                  "at": "2025.Q2",
                  "status": "unaffected"
                }
              ],
              "version": "0",
              "lessThan": "2025.Q2",
              "versionType": "Indoor Connect 8855"
            }
          ],
          "defaultStatus": "affected"
        }
      ]
    }
  ],
  "published": "2025-09-25T15:16:11.587",
  "references": [
    {
      "url": "https://www.ericsson.com/en/about-us/security/psirt/e2025-09-25",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf",
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Ericsson Indoor Connect 8855 contains a vulnerability where server-side security can be bypassed in the client which if exploited can lead to unauthorized disclosure of certain information."
    }
  ],
  "lastModified": "2026-06-17T09:22:12.480",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ericsson:indoor_connect_8855_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6C4EA917-1899-4713-AE19-50412249505A",
              "versionEndExcluding": "2025.q2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ericsson:indoor_connect_8855:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "3B0C1261-B15A-4D91-AC65-9834D16A94F1"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf"
}