CVE-2025-40812
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.14%
- Percentil entre todas las CVEs puntuadas: 3
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution90 % - Impacto principal
T1059Command and Scripting Interpreterexecution85 % - Impacto secundario
T1499.004Application or System Exploitationimpact80 %
Vector CVSS con AV:L y UI:P (requiere interacción del usuario) indica T1203. El texto menciona crash (DoS) o ejecución de código al parsear archivos PRT especialmente crafted, sustentando T1059 e impacto de disponibilidad (T1499.004).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (2)
CWE
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-40812",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-40812",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-10-14T19:04:30.294501Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.3,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Solid Edge SE2024",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V224.0 Update 14",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Solid Edge SE2025",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V225.0 Update 6",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-10-14T10:15:40.090",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-541582.html",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 14), Solid Edge SE2025 (All versions < V225.0 Update 6). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
}
],
"lastModified": "2026-06-17T09:22:09.943",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "893736B3-0140-4775-8700-CB9D7719DDE5"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A0119E8F-1FAF-4A3B-B6E9-20F78360FC82"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "829C4AEB-7C8D-408B-A79C-8684753F45E1"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00010:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8E262AB3-8C47-430A-9D42-89317CB630C5"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00011:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "94758C94-F427-480E-A9F1-109D8660C4E0"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00012:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D084D11C-08FB-4EEE-A5E3-D93C10103D2A"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_00013:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F8A834C5-1E45-4087-A3A4-C059A2C9960C"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1E8FB23E-280D-46FD-BD44-5D4552639E00"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0003:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CA2417A0-DD31-46FC-8D5A-9128B86C9352"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0004:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3CA9C494-767C-4CFA-AB07-106298B7B2C4"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0005:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C3738D73-82A5-41E4-8083-34611A6301BE"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0006:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5634352F-0DD1-4731-9E43-61D0A9A40D1B"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0007:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "32E3D549-54F0-4909-830D-BDE8CDAD5AF7"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0008:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1137D7B3-17AD-4997-AC19-4308AA5C9438"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0009:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E5488DEB-3165-4F88-8C63-7B9BC212DEFF"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:-:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9EBC379B-A9D5-4587-87A1-59D2D8EF2267"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3D717792-2F86-43CD-973B-249171094C6C"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0001:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2C6F3C20-8AB5-4A6A-8524-C7CBC4A4D973"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0002:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "03CCA3A8-F8D6-4C80-BC03-15B865CE46B7"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0003:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B51556E8-9A3B-4755-BC2C-8FACABC01A7B"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0004:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "737A4807-387D-4099-880D-2CCEE7B77B44"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge_se2025:225.0:update_0005:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9267F09C-5EFD-443F-ABE0-974C1D034464"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}