CVE-2025-40740
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.15%
- Percentil entre todas las CVEs puntuadas: 4
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1203Exploitation for Client Executionexecution92 % - Impacto principal
T1059Command and Scripting Interpreterexecution85 %
AV:L + UI:P indica ejecución en el cliente (abrir archivo PAR preparado); CWE-125 (out of bounds read) + descripción permiten RCE en el proceso.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-40740",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-40740",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-07-08T20:33:07.675178Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.3,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "Solid Edge SE2025",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V225.0 Update 5",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-07-08T11:15:30.560",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-091753.html",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files.\r\nThis could allow an attacker to execute code in the context of the current process."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Solid Edge SE2025 (todas las versiones anteriores a V225.0 Actualización 5). Las aplicaciones afectadas contienen una lectura fuera de los límites que excede el final de una estructura asignada al analizar archivos PAR especialmente manipulados. Esto podría permitir que un atacante ejecute código en el contexto del proceso actual."
}
],
"lastModified": "2026-06-17T09:22:03.490",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "53E41C1A-7AFC-48CC-94A7-F91947370206",
"versionEndIncluding": "se2025"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2025:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8FBC2B2E-046A-4C2B-9B5E-6680AC8D47F4"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2025:update_1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D780A197-50B1-49C2-BE74-105C2313D042"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2025:update_2:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "13634F0A-BE68-4F65-AC46-DAF91AF38FA1"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2025:update_3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1E5E5E60-5D91-4B7E-959F-56E7E66DA289"
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2025:update_4:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "157E2401-809E-4A5B-93A3-F1BF514A9ECA"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "productcert@siemens.com"
}