« Volver al listado

CVE-2025-40592

Estado: AplazadaMedia (4.6)—

A vulnerability has been identified in Mendix Studio Pro 10 (All versions < V10.24.24 for Windows), Mendix Studio Pro 10 (All versions < V10.24.24 for Mac), Mendix Studio Pro 11 (All versions < V11.13.0 for Windows), Mendix Studio Pro 11 (All versions < V11.13.0 for Mac), Mendix Studio Pro 11.12 (All versions < V11.12.2 for Windows), Mendix Studio Pro 11.12 (All versions < V11.12.2 for Mac), Mendix Studio Pro 11.6 (All versions < V11.6.9 for Windows), Mendix Studio Pro 11.6 (All versions < V11.6.9 for Mac), Mendix Studio Pro 9 (All versions < V9.24.44 for Windows).

Leer descripción completaMostrar menos

A zip path traversal vulnerability exists in the module installation process of Studio Pro. By crafting a malicious module and distributing it via (for example) the Mendix Marketplace, an attacker could write or modify arbitrary files in directories outside a developer’s project directory upon module installation.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-40592",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-40592",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-06-12T13:55:58.769656Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 6.1,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "HIGH",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 4,
        "exploitabilityScore": 1.6
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 4.6,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:N/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "ACTIVE",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "HIGH",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "NONE",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "Mendix Studio Pro 10",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V10.24.24",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Mendix Studio Pro 10",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V10.24.24",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Mendix Studio Pro 11",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V11.13.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Mendix Studio Pro 11",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V11.13.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Mendix Studio Pro 11.12",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V11.12.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Mendix Studio Pro 11.12",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V11.12.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Mendix Studio Pro 11.6",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V11.6.9",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Mendix Studio Pro 11.6",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V11.6.9",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Mendix Studio Pro 9",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V9.24.44",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2025-06-12T08:15:23.407",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-627195.html",
      "source": "productcert@siemens.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Mendix Studio Pro 10 (All versions < V10.24.24 for Windows), Mendix Studio Pro 10 (All versions < V10.24.24 for Mac), Mendix Studio Pro 11 (All versions < V11.13.0 for Windows), Mendix Studio Pro 11 (All versions < V11.13.0 for Mac), Mendix Studio Pro 11.12 (All versions < V11.12.2 for Windows), Mendix Studio Pro 11.12 (All versions < V11.12.2 for Mac), Mendix Studio Pro 11.6 (All versions < V11.6.9 for Windows), Mendix Studio Pro 11.6 (All versions < V11.6.9 for Mac), Mendix Studio Pro 9 (All versions < V9.24.44 for Windows). A zip path traversal vulnerability exists in the module installation process of Studio Pro. By crafting a malicious module and distributing it via (for example) the Mendix Marketplace, an attacker could write or modify arbitrary files in directories outside a developer’s project directory upon module installation."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Mendix Studio Pro 10 (todas las versiones &lt; V10.23.0), Mendix Studio Pro 10.12 (todas las versiones &lt; V10.12.17), Mendix Studio Pro 10.18 (todas las versiones &lt; V10.18.7), Mendix Studio Pro 10.6 (todas las versiones &lt; V10.6.24), Mendix Studio Pro 11 (todas las versiones), Mendix Studio Pro 8 (todas las versiones &lt; V8.18.35) y Mendix Studio Pro 9 (todas las versiones &lt; V9.24.35). Existe una vulnerabilidad de cruce de ruta zip en el proceso de instalación del módulo de Studio Pro. Al manipular un módulo malicioso y distribuirlo a través de (por ejemplo) Mendix Marketplace, un atacante podría escribir o modificar archivos arbitrarios en directorios externos al directorio del proyecto del desarrollador durante la instalación del módulo."
    }
  ],
  "lastModified": "2026-09-28T10:16:40.363",
  "sourceIdentifier": "productcert@siemens.com"
}