« Volver al listado

CVE-2025-4053

Estado: AplazadaMedia (6.8)—

The data stored in Be-Tech Mifare Classic card is stored in cleartext. An attacker having access to a Be-Tech hotel guest Mifare Classic card can create a master key card that unlocks all the locks in the building.

This issue affects all Be-Tech Mifare Classic card systems. To fix the vulnerability, it is necessary to replace the software, encoder, cards, and PCBs in the locks.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-4053",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-4053",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-05-27T14:23:45.443332Z"
        }
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "cvd@cert.pl",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 6.8,
          "Automatable": "NOT_DEFINED",
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "cvd@cert.pl",
      "affectedData": [
        {
          "vendor": "Be-Tech",
          "product": "Mifare Classic cards",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "*"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-05-26T10:15:21.190",
  "references": [
    {
      "url": "https://cert.pl/en/posts/2025/05/CVE-2025-4053/",
      "source": "cvd@cert.pl"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cvd@cert.pl",
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "The data stored in Be-Tech Mifare Classic card is stored in cleartext. An attacker having access to a Be-Tech hotel guest Mifare Classic card can create a master key card that unlocks all the locks in the building. \n\nThis issue affects all Be-Tech Mifare Classic card systems. To fix the vulnerability, it is necessary to replace the software, encoder, cards, and PCBs in the locks."
    },
    {
      "lang": "es",
      "value": "Los datos almacenados en la tarjeta Be-Tech Mifare Classic se almacenan en texto plano. Un atacante con acceso a la tarjeta Mifare Classic de un huésped de un hotel Be-Tech puede crear una tarjeta maestra que desbloquea todas las cerraduras del edificio. Este problema afecta a todos los sistemas de tarjetas Be-Tech Mifare Classic. Para solucionar la vulnerabilidad, es necesario reemplazar el software, el codificador, las tarjetas y las placas de circuito impreso (PCB) de las cerraduras."
    }
  ],
  "lastModified": "2026-06-17T09:32:23.843",
  "sourceIdentifier": "cvd@cert.pl"
}