CVE-2025-36744
Status: AnalyzedLow (2.4)—
SolarEdge SE3680H has unauthenticated disclosure of sensitive information during the bootloader loop. While the device repeatedly initializes and waits for boot instructions, the bootloader emits diagnostic output this behavior can leak operating system information.
CVSS
- Version: 4.0
- Vector: CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:X/R:X/V:X/RE:X/U:X
- Base score: 2.4
Exploitation probability (EPSS)
- Probability of exploitation in the next 30 days: 0.16%
- Percentile among all scored CVEs: 5
- Score date: 10/5/2026
EPSS (Exploit Prediction Scoring System, FIRST) estimates how likely a vulnerability is to be exploited in the wild within 30 days. It complements CVSS (impact) and CISA KEV (confirmed exploitation).
Affected technologies (1)
CWEs
- NVD-CWE-Other
References
Raw JSON (NVD)
Show
{
"id": "CVE-2025-36744",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-36744",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-12-12T19:31:06.783164Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 2.4,
"attackVector": "PHYSICAL",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 0.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "csirt@divd.nl",
"cvssData": {
"Safety": "NEGLIGIBLE",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 2.4,
"Automatable": "NOT_DEFINED",
"attackVector": "PHYSICAL",
"baseSeverity": "LOW",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "csirt@divd.nl",
"affectedData": [
{
"vendor": "SolarEdge",
"product": "SE3680H",
"versions": [
{
"status": "affected",
"version": "4.0",
"lessThan": "4.22",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-12-12T15:15:53.050",
"references": [
{
"url": "https://csirt.divd.nl/CVE-2025-36744",
"tags": [
"Third Party Advisory"
],
"source": "csirt@divd.nl"
},
{
"url": "https://csirt.divd.nl/DIVD-2025-00022/",
"tags": [
"Broken Link"
],
"source": "csirt@divd.nl"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SolarEdge SE3680H has unauthenticated disclosure of sensitive information during the bootloader loop. While the device repeatedly initializes and waits for boot instructions, the bootloader emits diagnostic output this behavior can leak operating system information."
}
],
"lastModified": "2026-06-17T09:14:53.443",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:solaredge:se3680h_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1525CFCE-58DC-428A-B3A5-FE97E306C581",
"versionEndExcluding": "4.22",
"versionStartIncluding": "4.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:solaredge:se3680h:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CF1A53FC-7C47-46A1-8A50-9FDF74A350C7"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "csirt@divd.nl"
}