« Volver al listado

CVE-2025-34029

Estado: ModificadaCrítica (9.4)—

An OS command injection vulnerability exists in the Edimax EW-7438RPn Mini firmware version 1.13 and prior via the syscmd.asp form handler. The /goform/formSysCmd endpoint exposes a system command interface through the sysCmd parameter. A remote authenticated attacker can submit arbitrary shell commands directly, resulting in command execution as the root user. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Acceso remoto autenticado (PR:L) a endpoint de servicios remotos (/goform/formSysCmd) permite inyección de comandos OS (CWE-78) como root. T1210 + T1059 + escalada implícita (T1068).

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-34029",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-34029",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-06-23T20:41:13.971995Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "disclosure@vulncheck.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 9.4,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "subIntegrityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "HIGH",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "disclosure@vulncheck.com",
      "affectedData": [
        {
          "vendor": "Edimax",
          "modules": [
            "Web Management Interface (syscmd.asp system command interface)"
          ],
          "product": "Edimax EW-7438RPn Mini",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "1.13"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-06-20T19:15:37.210",
  "references": [
    {
      "url": "https://vulncheck.com/advisories/edimax-ew-7438rpn-command-injections",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.broadcom.com/support/security-center/attacksignatures/detail?asid=32163",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.edimax.com/edimax/merchandise/merchandise_detail/data/edimax/global/wi-fi_range_extenders_n300/ew-7438rpn_mini/",
      "tags": [
        "Product"
      ],
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.exploit-db.com/exploits/48377",
      "tags": [
        "Exploit",
        "VDB Entry"
      ],
      "source": "disclosure@vulncheck.com"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "disclosure@vulncheck.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An OS command injection vulnerability exists in the Edimax EW-7438RPn Mini firmware version 1.13 and prior via the syscmd.asp form handler. The /goform/formSysCmd endpoint exposes a system command interface through the sysCmd parameter. A remote authenticated attacker can submit arbitrary shell commands directly, resulting in command execution as the root user. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de inyección de comandos del sistema operativo en el firmware 1.13 y anteriores del Edimax EW-7438RPn Mini a través del controlador de formularios syscmd.asp. El endpoint /goform/formSysCmd expone una interfaz de comandos del sistema mediante el parámetro sysCmd. Un atacante remoto autenticado puede enviar comandos de shell arbitrarios directamente, lo que resulta en la ejecución del comando como usuario root."
    }
  ],
  "lastModified": "2026-06-17T09:13:20.200",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:edimax:ew-7438rpn_mini_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "82AD0A5F-41F6-480D-AF55-88F0F768B669",
              "versionEndIncluding": "1.13"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:edimax:ew-7438rpn_mini:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "883D1C81-1FD3-45CE-B1D8-85E760F4FF14"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "disclosure@vulncheck.com"
}