CVE-2025-32010
A stack-based buffer overflow vulnerability exists in the Cloud API functionality of Tenda AC6 V5.0 V02.03.01.110. A specially crafted HTTP response can lead to arbitrary code execution. An attacker can send an HTTP response to trigger this vulnerability.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.69%
- Percentil entre todas las CVEs puntuadas: 51
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access95 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 %
Buffer overflow en API remota accesible sin autenticación (AV:N/PR:N) permitiendo ejecución de código arbitrario; el vector CVSS crítico y la descripción de 'arbitrary code execution' sustentan ambas técnicas.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-121
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-32010",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-32010",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-08-20T13:53:04.886277Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "talos-cna@cisco.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.2
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "talos-cna@cisco.com",
"affectedData": [
{
"vendor": "Tenda",
"product": "AC6 V5.0",
"versions": [
{
"status": "affected",
"version": "V02.03.01.110"
}
]
}
]
}
],
"published": "2025-08-20T14:15:43.557",
"references": [
{
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2025-2168",
"tags": [
"Third Party Advisory"
],
"source": "talos-cna@cisco.com"
},
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2168",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "talos-cna@cisco.com",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stack-based buffer overflow vulnerability exists in the Cloud API functionality of Tenda AC6 V5.0 V02.03.01.110. A specially crafted HTTP response can lead to arbitrary code execution. An attacker can send an HTTP response to trigger this vulnerability."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de desbordamiento de búfer en la pila de la API de nube de Tenda AC6 V5.0 V02.03.01.110. Una respuesta HTTP especialmente manipulada puede provocar la ejecución de código arbitrario. Un atacante puede enviar una respuesta HTTP para activar esta vulnerabilidad."
}
],
"lastModified": "2026-06-17T09:11:18.883",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:ac6_firmware:02.03.01.110:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FBBF7445-03C8-48EA-9DC3-BD4825E7CC0A"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:ac6:5.0:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CFBE582F-BE50-4810-AAB2-B19F40693ACE"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "talos-cna@cisco.com"
}