CVE-2025-3020
Estado: AplazadaMedia (5.4)—
An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N
- Puntuación base: 5.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.28%
- Percentil entre todas las CVEs puntuadas: 19
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
CWE
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-3020",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-3020",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-05-06T13:52:10.556193Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.4,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 2.5,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "info@cert.vde.com",
"affectedData": [
{
"vendor": "Wiesemann & Theis",
"product": "ERP-Gateway 12x Digital Input, 6x Digital Relais",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "ERP-Gateway 2x Digital Input, 2x Digital Output",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "ERP-Gateway 2x Digital PoE",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-Alarm 6x6 DigitalWeb-Alarm 6x6 Digital",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-Count 6x Digital",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "3.79",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-Graph Air Quality",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO 12x Digital Input, 6x Digital Relais",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO 12x Digital Input, 6x Digital Relais",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO 12x Digital Input, 6x Digital Relais",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO Analog-In/Out 2x 0/4..20mA PoE",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO Digital 12xIn, 12xOut",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO Digital 12xIn, 12xOut",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO Digital 12xIn, 12xOut",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "4.08",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO Digital 12xIn, 12xOut, 1xRS232",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO Digital 12xIn, 12xOut, 1xRS232",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO Digital 2xIn, 2xOut",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO Digital 2xIn, 2xOut",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO Digital 2xIn, 2xOut",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-IO Digital Logger 6xIn, 6xOut",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "3.70",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-Thermograph 2x",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-Thermograph 8x",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-Thermograph NTC",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-Thermograph NTC PoE",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-Thermograph Pt100 / Pt1000",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-Thermograph Pt100 / Pt1000 PoE",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-Thermograph Relais",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-Thermo-Hygrobarograph",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Wiesemann & Theis",
"product": "Web-Thermo-Hygrograph",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-05-06T08:15:16.397",
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2025-032",
"source": "info@cert.vde.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "info@cert.vde.com",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact."
},
{
"lang": "es",
"value": "Un atacante remoto con pocos privilegios puede ejecutar scripts web o HTML arbitrarios a través de un payload manipulado inyectado en varios campos de la página web de configuración con un impacto limitado."
}
],
"lastModified": "2026-06-17T09:19:02.180",
"sourceIdentifier": "info@cert.vde.com"
}