CVE-2025-27926
Estado: AnalizadaMedia (5.3)—
In Nintex Automation 5.6 and 5.7 before 5.8, the K2 SmartForms Designer folder has configuration files (web.config) containing passwords that are readable by unauthorized users.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.35%
- Percentil entre todas las CVEs puntuadas: 26
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-276
- CWE-522
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-27926",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-27926",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-03-11T13:36:29.280050Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cve@mitre.org",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 4.3,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 2.5
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "Nintex",
"product": "Automation",
"versions": [
{
"status": "affected",
"version": "5.6",
"lessThan": "5.8",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-03-10T23:15:35.670",
"references": [
{
"url": "https://help.nintex.com/en-US/platform/ReleaseNotes/K2Five.htm",
"tags": [
"Release Notes"
],
"source": "cve@mitre.org"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cve@mitre.org",
"description": [
{
"lang": "en",
"value": "CWE-276"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-522"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Nintex Automation 5.6 and 5.7 before 5.8, the K2 SmartForms Designer folder has configuration files (web.config) containing passwords that are readable by unauthorized users."
},
{
"lang": "es",
"value": "En Nintex Automation 5.6 y 5.7 anteriores a 5.8, la carpeta K2 SmartForms Designer tiene archivos de configuración (web.config) que contienen contraseñas que pueden leer usuarios no autorizados."
}
],
"lastModified": "2026-06-17T09:04:24.237",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:nintex:automation:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7DFACECA-465E-4F67-9BED-F817C7F6BACD",
"versionEndExcluding": "5.8",
"versionStartIncluding": "5.6"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}