CVE-2025-27462
[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.]
The Windows PV drivers expose various facilities to userspace. Several of these have no security descriptor, and are therefore fully accessible to unprivileged users. These are:
Detalles técnicos trazas, registros y código del informe original
1. XenCons, CVE-2025-27462 2. XenIface, CVE-2025-27463 3. XenBus, CVE-2025-27464
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 9.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.16%
- Percentil entre todas las CVEs puntuadas: 4
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1068Exploitation for Privilege Escalationprivilege escalation95 % - Impacto principal
T1222File and Directory Permissions Modificationdefense impairment90 %
AV:L sin UI:R indica escalada local; CWE-276 (permisos insuficientes) en drivers PV de Xen expone facilidades a usuarios sin privilegios, permitiendo modificar permisos (T1222) y potencial ejecución de código.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (4)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-276
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-27462",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-27462",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-07-09T16:06:53.503103Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "security@xen.org",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 9.4,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "security@xen.org",
"affectedData": [
{
"vendor": "Xen",
"product": "Windows PV drivers",
"versions": [
{
"status": "affected",
"version": "all"
}
],
"platforms": [
"Windows"
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-07-09T16:16:33.070",
"references": [
{
"url": "https://xenbits.xen.org/xsa/advisory-468.html",
"source": "security@xen.org"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "security@xen.org",
"description": [
{
"lang": "en",
"value": "CWE-276"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.]\n\n\nThe Windows PV drivers expose various facilities to userspace. Several\nof these have no security descriptor, and are therefore fully accessible\nto unprivileged users. These are:\n\n 1. XenCons, CVE-2025-27462\n 2. XenIface, CVE-2025-27463\n 3. XenBus, CVE-2025-27464"
},
{
"lang": "es",
"value": "[Este registro de información de la CNA se relaciona con múltiples CVE; el texto explica qué aspectos/vulnerabilidades corresponden a qué CVE.]\n\nLos controladores PV de Windows exponen diversas funcionalidades al espacio de usuario. Varias de estas no tienen descriptor de seguridad y, por lo tanto, son totalmente accesibles para usuarios sin privilegios. Estas son:\n\n 1. XenCons, CVE-2025-27462\n 2. XenIface, CVE-2025-27463\n 3. XenBus, CVE-2025-27464"
}
],
"lastModified": "2026-09-29T19:10:00.160",
"sourceIdentifier": "security@xen.org"
}