« Volver al listado

CVE-2025-27462

Estado: AplazadaCrítica (9.4)—

[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.]

The Windows PV drivers expose various facilities to userspace. Several of these have no security descriptor, and are therefore fully accessible to unprivileged users. These are:

Detalles técnicos trazas, registros y código del informe original
  1. XenCons,  CVE-2025-27462
  2. XenIface, CVE-2025-27463
  3. XenBus,   CVE-2025-27464

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

AV:L sin UI:R indica escalada local; CWE-276 (permisos insuficientes) en drivers PV de Xen expone facilidades a usuarios sin privilegios, permitiendo modificar permisos (T1222) y potencial ejecución de código.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (4)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-27462",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-27462",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-07-09T16:06:53.503103Z"
        }
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "security@xen.org",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 9.4,
          "Automatable": "NOT_DEFINED",
          "attackVector": "LOCAL",
          "baseSeverity": "CRITICAL",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "HIGH",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "security@xen.org",
      "affectedData": [
        {
          "vendor": "Xen",
          "product": "Windows PV drivers",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ],
          "platforms": [
            "Windows"
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2026-07-09T16:16:33.070",
  "references": [
    {
      "url": "https://xenbits.xen.org/xsa/advisory-468.html",
      "source": "security@xen.org"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "security@xen.org",
      "description": [
        {
          "lang": "en",
          "value": "CWE-276"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.]\n\n\nThe Windows PV drivers expose various facilities to userspace.  Several\nof these have no security descriptor, and are therefore fully accessible\nto unprivileged users.  These are:\n\n  1. XenCons,  CVE-2025-27462\n  2. XenIface, CVE-2025-27463\n  3. XenBus,   CVE-2025-27464"
    },
    {
      "lang": "es",
      "value": "[Este registro de información de la CNA se relaciona con múltiples CVE; el texto explica qué aspectos/vulnerabilidades corresponden a qué CVE.]\n\nLos controladores PV de Windows exponen diversas funcionalidades al espacio de usuario. Varias de estas no tienen descriptor de seguridad y, por lo tanto, son totalmente accesibles para usuarios sin privilegios. Estas son:\n\n  1. XenCons, CVE-2025-27462\n  2. XenIface, CVE-2025-27463\n  3. XenBus, CVE-2025-27464"
    }
  ],
  "lastModified": "2026-09-29T19:10:00.160",
  "sourceIdentifier": "security@xen.org"
}