CVE-2025-27398
Estado: AnalizadaBaja (2.1)—
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly neutralize special characters when interpreting user controlled log paths. This could allow an authenticated highly-privileged remote attacker to execute a limited set of binaries that are already present on the filesystem.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 2.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.34%
- Percentil entre todas las CVEs puntuadas: 25
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-27398",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-27398",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-03-11T13:29:17.137806Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 2.7,
"attackVector": "NETWORK",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 1.2
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 2.1,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "LOW",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "HIGH",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "SCALANCE LPE9403",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V4.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-03-11T10:15:19.247",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-075201.html",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly neutralize special characters when interpreting user controlled log paths.\r\nThis could allow an authenticated highly-privileged remote attacker to execute a limited set of binaries that are already present on the filesystem."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (todas las versiones anteriores a la V4.0). Los dispositivos afectados no neutralizan correctamente los caracteres especiales al interpretar las rutas de registro controladas por el usuario. Esto podría permitir que un atacante remoto autenticado y con privilegios elevados ejecute un conjunto limitado de archivos binarios que ya están presentes en el sistema de archivos."
}
],
"lastModified": "2026-06-17T09:03:30.770",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_lpe9403_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1F8FD0DA-AB97-43DC-A9FB-DEFB7804036B",
"versionEndExcluding": "4.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_lpe9403:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "52A77C9D-E59C-4397-B834-797D7B334A6B"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "productcert@siemens.com"
}