Estado: AplazadaMedia (6.1)—

A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-27253",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-27253",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-03-10T15:33:39.489617Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "prodsec@nozominetworks.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 6.1,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "prodsec@nozominetworks.com",
      "affectedData": [
        {
          "vendor": "GE Vernova",
          "product": "N60 multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "B30 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "B90 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "C30 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "C60 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "C70 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "C95 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "D30 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "D60 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "F35 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "F60 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "G30 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "G60 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "L30 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "L60 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "L90 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "M60 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "T35 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "T60 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "GE Vernova",
          "product": "M60 Multilin",
          "versions": [
            {
              "status": "affected",
              "version": "7.0",
              "versionType": "custom",
              "lessThanOrEqual": "8.60"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-03-10T09:15:10.897",
  "references": [
    {
      "url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily&type=21&file=76",
      "source": "prodsec@nozominetworks.com"
    },
    {
      "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-27253",
      "source": "prodsec@nozominetworks.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "prodsec@nozominetworks.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-15"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-15 \"External Control of System or Configuration Setting\" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network."
    },
    {
      "lang": "es",
      "value": "Una validación de entrada incorrecta en los dispositivos de la familia GE Vernova UR IED de la versión 7.0 a la 8.60 permite a un atacante proporcionar una entrada que establezca una conexión TCP a través de un reenvío de puerto. La falta de validación de la dirección IP y del puerto puede permitir al atacante eludir las reglas del firewall o enviar tráfico malicioso en la red."
    }
  ],
  "lastModified": "2026-06-17T09:03:16.997",
  "sourceIdentifier": "prodsec@nozominetworks.com"
}