CVE-2025-27080
Estado: AplazadaMedia (6)—
Vulnerabilities in the command line interface of AOS-CX could allow an authenticated remote attacker to expose sensitive information. Successful exploitation could allow an attacker to gain unauthorized access to services outside of the impacted switch, potentially leading to lateral movement involving those services.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N
- Puntuación base: 6
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.19%
- Percentil entre todas las CVEs puntuadas: 8
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-359
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-27080",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-27080",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-03-18T19:32:04.221989Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "security-alert@hpe.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 6,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 4,
"exploitabilityScore": 1.5
}
]
},
"affected": [
{
"source": "security-alert@hpe.com",
"affectedData": [
{
"vendor": "Hewlett Packard Enterprise (HPE)",
"product": "AOS-CX",
"versions": [
{
"status": "affected",
"version": "10.10.0000",
"versionType": "semver",
"lessThanOrEqual": "<=10.10.1140"
},
{
"status": "affected",
"version": "10.13.0000",
"versionType": "semver",
"lessThanOrEqual": "<=10.13.1070"
},
{
"status": "affected",
"version": "10.14.0000",
"versionType": "semver",
"lessThanOrEqual": "<=10.14.1030"
},
{
"status": "affected",
"version": "10.15.0000",
"versionType": "semver",
"lessThanOrEqual": "<=10.15.1000"
}
],
"defaultStatus": "affected"
}
]
}
],
"published": "2025-03-18T19:15:50.680",
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04818en_us&docLocale=en_US",
"source": "security-alert@hpe.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-359"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Vulnerabilities in the command line interface of AOS-CX could allow an authenticated remote attacker to expose sensitive information. Successful exploitation could allow an attacker to gain unauthorized access to services outside of the impacted switch, potentially leading to lateral movement involving those services."
},
{
"lang": "es",
"value": "Las vulnerabilidades en la interfaz de línea de comandos de AOS-CX podrían permitir que un atacante remoto autenticado exponga información confidencial. Una explotación exitosa podría permitir que un atacante obtenga acceso no autorizado a servicios fuera del conmutador afectado, lo que podría provocar un movimiento lateral que afecte a dichos servicios."
}
],
"lastModified": "2026-06-17T09:02:59.673",
"sourceIdentifier": "security-alert@hpe.com"
}