CVE-2025-27028
Estado: AplazadaMedia (6.8)—
The Linux deprivileged user vpuser in Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) can read the entire file system content, including files belonging to other users and having restricted access (like, for example, the root password hash).
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N
- Puntuación base: 6.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.29%
- Percentil entre todas las CVEs puntuadas: 20
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-266
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-27028",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-27028",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-07-09T13:30:51.594528Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 6.8,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 4,
"exploitabilityScore": 2.3
}
]
},
"affected": [
{
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"affectedData": [
{
"vendor": "Radiflow",
"product": "iSAP Smart Collector",
"versions": [
{
"status": "affected",
"version": "1.20",
"lessThan": "3.02-1",
"versionType": "semver"
}
],
"platforms": [
"Linux"
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-07-09T09:15:26.850",
"references": [
{
"url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2025-27028",
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158",
"description": [
{
"lang": "en",
"value": "CWE-266"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Linux deprivileged user vpuser in Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) can read the entire file system content, including files belonging to other users and having restricted access (like, for example, the root password hash)."
},
{
"lang": "es",
"value": "El usuario sin privilegios de Linux vpuser en Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) puede leer todo el contenido del sistema de archivos, incluidos los archivos que pertenecen a otros usuarios y que tienen acceso restringido (como, por ejemplo, el hash de la contraseña root)."
}
],
"lastModified": "2026-06-17T09:02:47.280",
"sourceIdentifier": "a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"
}