Weak encoding for password vulnerability exists in HMI ViewJet C-more series. If this vulnerability is exploited, authentication information may be obtained by a local authenticated attacker.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-26401",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-26401",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-04T14:20:14.818790Z"
        }
      }
    ],
    "cvssMetricV30": [
      {
        "type": "Secondary",
        "source": "vultures@jpcert.or.jp",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.0",
          "baseScore": 6.5,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 4,
        "exploitabilityScore": 2
      }
    ]
  },
  "affected": [
    {
      "source": "vultures@jpcert.or.jp",
      "affectedData": [
        {
          "vendor": "JTEKT ELECTRONICS CORPORATION",
          "product": "HMI ViewJet C-more series",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ]
    }
  ],
  "published": "2025-04-04T02:15:18.047",
  "references": [
    {
      "url": "https://jvn.jp/en/jp/JVN17260367/",
      "source": "vultures@jpcert.or.jp"
    },
    {
      "url": "https://www.electronics.jtekt.co.jp/en/topics/202503207271/",
      "source": "vultures@jpcert.or.jp"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "vultures@jpcert.or.jp",
      "description": [
        {
          "lang": "en",
          "value": "CWE-261"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Weak encoding for password vulnerability exists in HMI ViewJet C-more series. If this vulnerability is exploited, authentication information may be obtained by a local authenticated attacker."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de codificación débil para contraseñas en la serie HMI ViewJet C-more. Si se explota esta vulnerabilidad, un atacante local autenticado podría obtener información de autenticación."
    }
  ],
  "lastModified": "2026-06-17T09:01:42.640",
  "sourceIdentifier": "vultures@jpcert.or.jp"
}