CVE-2025-2605
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 14%
- Percentil entre todas las CVEs puntuadas: 97
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 % - Impacto secundario
T1068Exploitation for Privilege Escalationprivilege escalation75 %
CWE-78 (command injection) en servicio remoto con PR:L indica explotación remota de servicios que requiere autenticación previa (T1210). El atacante ejecuta comandos del SO (T1059) y escala privilegios (T1068) según 'Privilege Abuse' en descripción.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (2)
CWE
- CWE-78
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-2605",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-2605",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-05-02T13:32:21.228869Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt@honeywell.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 9.9,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 3.1
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "psirt@honeywell.com",
"affectedData": [
{
"vendor": "Honeywell",
"product": "MB-Secure",
"versions": [
{
"status": "affected",
"version": "V11.04",
"lessThan": "V12.53",
"versionType": "semver"
}
],
"defaultStatus": "affected"
}
]
}
],
"published": "2025-05-02T13:15:46.440",
"references": [
{
"url": "https://www.honeywell.com/us/en/product-security#security-notices",
"tags": [
"Vendor Advisory"
],
"source": "psirt@honeywell.com"
},
{
"url": "http://seclists.org/fulldisclosure/2025/May/19",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@honeywell.com",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB-Secure allows Privilege Abuse. This issue affects MB-Secure: from V11.04 before V12.53 and MB-Secure PRO from V01.06 before V03.09.Honeywell also recommends updating to the most recent version of this product."
},
{
"lang": "es",
"value": "La vulnerabilidad de neutralización incorrecta de elementos especiales utilizados en un comando del sistema operativo ('Inyección de comandos del sistema operativo') en Honeywell MB-Secure permite el abuso de privilegios. Este problema afecta a MB-Secure desde la versión 11.04 hasta la 12.53 y a MB-Secure PRO desde la versión 01.06 hasta la 03.09. Honeywell también recomienda actualizar a la versión más reciente de este producto."
}
],
"lastModified": "2026-06-17T09:07:16.293",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:honeywell:mb-secure_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9A3948BD-0AA0-4F44-87DE-6F93FE58A3CC",
"versionEndExcluding": "12.53",
"versionStartIncluding": "11.04"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:honeywell:mb-secure:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "068F05DB-54F1-4F6B-8A1B-501E7841469B"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:honeywell:mb-secure_pro_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D6782306-FD38-4001-9F99-9B1A9EC820F9",
"versionEndExcluding": "03.09",
"versionStartIncluding": "01.06"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:honeywell:mb-secure_pro:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F8F28351-A605-4F24-B62B-408D77C661E7"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "psirt@honeywell.com"
}