CVE-2025-25061
Estado: AplazadaMedia (5.8)—
Unintended proxy or intermediary ('Confused Deputy') issue exists in HMI ViewJet C-more series and HMI GC-A2 series, which may allow a remote unauthenticated attacker to use the product as an intermediary for FTP bounce attack.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N
- Puntuación base: 5.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.46%
- Percentil entre todas las CVEs puntuadas: 37
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-441
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-25061",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-25061",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-04-04T14:20:50.585279Z"
}
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "vultures@jpcert.or.jp",
"cvssData": {
"scope": "CHANGED",
"version": "3.0",
"baseScore": 5.8,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "vultures@jpcert.or.jp",
"affectedData": [
{
"vendor": "JTEKT ELECTRONICS CORPORATION",
"product": "HMI ViewJet C-more series",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"vendor": "JTEKT ELECTRONICS CORPORATION",
"product": "HMI GC-A2 series",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
]
}
],
"published": "2025-04-04T02:15:17.910",
"references": [
{
"url": "https://jvn.jp/en/jp/JVN17260367/",
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://www.electronics.jtekt.co.jp/en/topics/202503207269/",
"source": "vultures@jpcert.or.jp"
},
{
"url": "https://www.electronics.jtekt.co.jp/en/topics/202503207271/",
"source": "vultures@jpcert.or.jp"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "vultures@jpcert.or.jp",
"description": [
{
"lang": "en",
"value": "CWE-441"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unintended proxy or intermediary ('Confused Deputy') issue exists in HMI ViewJet C-more series and HMI GC-A2 series, which may allow a remote unauthenticated attacker to use the product as an intermediary for FTP bounce attack."
},
{
"lang": "es",
"value": "Existe un problema de proxy o intermediario no deseado ('Confused Deputy') en las series HMI ViewJet C-more y HMI GC-A2, que puede permitir que un atacante remoto no autenticado use el producto como intermediario para un ataque de rebote de FTP."
}
],
"lastModified": "2026-06-17T09:00:13.553",
"sourceIdentifier": "vultures@jpcert.or.jp"
}