CVE-2025-25037
An information disclosure vulnerability exists in Aquatronica Controller System firmware versions <= 5.1.6 and web interface versions <= 2.0. The tcp.php endpoint fails to restrict unauthenticated access, allowing remote attackers to issue crafted POST requests and retrieve sensitive configuration data, including plaintext administrative credentials. Exploitation of this flaw can lead to full compromise of the system, enabling unauthorized manipulation of connected devices and aquarium parameters.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 9.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.57%
- Percentil entre todas las CVEs puntuadas: 75
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access95 % - Impacto principal
T1005Data from Local Systemcollection90 % - Impacto secundario
T1078.001Default Accountsstealth · persistence · privilege escalation · initial access85 %
AV:N/PR:N indica explotación remota sin privilegios (T1190). El endpoint tcp.php no autenticado expone datos sensibles y credenciales en texto plano, permitiendo lectura (T1005) y robo de cuentas administrativas (T1078.001) para manipulación posterior de dispositivos (T1565.001).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-200
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-25037",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-25037",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-06-23T20:32:57.296954Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 9.3,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "disclosure@vulncheck.com",
"affectedData": [
{
"vendor": "Aquatronica",
"modules": [
"Web Management Interface (tcp.php endpoint)"
],
"product": "Aquatronica Controller System",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "semver",
"lessThanOrEqual": "5.1.6"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-06-20T19:15:35.870",
"references": [
{
"url": "https://fortiguard.fortinet.com/encyclopedia/ips/56008",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://vulncheck.com/advisories/aquatronica-controller-system-credential-leak",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://www.aquatronica.com",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://www.exploit-db.com/exploits/52028",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2024-5824.php",
"source": "disclosure@vulncheck.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "disclosure@vulncheck.com",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An information disclosure vulnerability exists in Aquatronica Controller System firmware versions <= 5.1.6 and web interface versions <= 2.0. The tcp.php endpoint fails to restrict unauthenticated access, allowing remote attackers to issue crafted POST requests and retrieve sensitive configuration data, including plaintext administrative credentials. Exploitation of this flaw can lead to full compromise of the system, enabling unauthorized manipulation of connected devices and aquarium parameters."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de divulgación de información en las versiones de firmware de Aquatronica Controller System anteriores a la 5.1.6 y anteriores a la 2.0 de la interfaz web. El endpoint tcp.php no restringe el acceso no autenticado, lo que permite a atacantes remotos emitir solicitudes POST manipuladas y recuperar datos de configuración confidenciales, incluyendo credenciales administrativas en texto plano. La explotación de esta vulnerabilidad puede comprometer por completo el sistema, lo que permite la manipulación no autorizada de los dispositivos conectados y los parámetros del acuario."
}
],
"lastModified": "2026-06-17T09:00:10.840",
"sourceIdentifier": "disclosure@vulncheck.com"
}