CVE-2025-24938
The web application allows user input to pass unfiltered to a command executed on the underlying operating system. An attacker with high privileged access (administrator) to the application has the potential execute commands on the operating system under the context of the webserver.
The vulnerable component is bound to the network stack and the set of possible attackers extends up to and including the entire Internet. Has the potential to inject command while creating a new User from User Management.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
- Puntuación base: 8.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.30%
- Percentil entre todas las CVEs puntuadas: 21
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1059Command and Scripting Interpreterexecution85 %
AV:A/PR:H indica acceso de red adyacente con privilegios altos; inyección de comandos OS (CWE-78) permite ejecución remota. T1210 por red adyacente con requerimientos de privilegio; T1059 por ejecución de comandos no especificada en intérprete concreto.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-78
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-24938",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-24938",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-07-23T18:34:24.206505Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 8.4,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 1.7
}
]
},
"affected": [
{
"source": "b48c3b8f-639e-4c16-8725-497bc411dad0",
"affectedData": [
{
"vendor": "Nokia",
"product": "WaveSuite NOC",
"versions": [
{
"status": "affected",
"version": "WS-NOC 24.6, WS-NOC 23.6 and WS-NOC 23.12"
},
{
"status": "unaffected",
"version": "WS-NOC 24.6 FP3"
}
]
}
]
}
],
"published": "2025-07-21T07:15:24.130",
"references": [
{
"url": "https://www.nokia.com/about-us/security-and-privacy/product-security-advisory/cve-2025-24938/",
"tags": [
"Vendor Advisory"
],
"source": "b48c3b8f-639e-4c16-8725-497bc411dad0"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The web application allows user input to pass unfiltered to a command executed on the underlying operating system. An attacker with high privileged access (administrator) to the application has the potential execute commands on the operating system under the context of the webserver.\n\nThe vulnerable component is bound to the network stack and the set of possible attackers extends up to and including the entire Internet. Has the potential to inject command while creating a new User from User Management."
},
{
"lang": "es",
"value": "La aplicación web permite que la entrada del usuario se transfiera sin filtrar a un comando que se ejecuta en el sistema operativo subyacente. Un atacante con privilegios elevados (administrador) a la aplicación podría ejecutar comandos en el sistema operativo en el contexto del servidor web. El componente vulnerable está vinculado a la pila de red y el conjunto de posibles atacantes se extiende a toda Internet. Tiene el potencial de inyectar comandos al crear un nuevo usuario desde la Administración de Usuarios."
}
],
"lastModified": "2026-06-17T08:59:51.990",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:nokia:wavesuite_noc:23.6:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "557A2709-02CD-41F2-8D39-591C55DBC6CB"
},
{
"criteria": "cpe:2.3:a:nokia:wavesuite_noc:23.12:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3A4BF10D-5F41-49B7-AF3F-BAC85C6D8A15"
},
{
"criteria": "cpe:2.3:a:nokia:wavesuite_noc:24.6:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9CA0E502-BCDA-4616-A4D2-0DBBC22163DA"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "b48c3b8f-639e-4c16-8725-497bc411dad0"
}